114
Compressor 2
Parameter
Code
Delivered condition Commission-
ing
Maintenance/
Service
"Enable compressor"
5100
0
"Enable use of compressor stage"
5112
15
"Primary source output"
5143
0
"Output compressor stage"
5130
Rated heating output
according to type
plate
External heat generator
Parameter
Code
Delivered condition Commission-
ing
Maintenance/
service
"Enable external heat source"
7B00
0
"Priority ext. heat source/instant. heating
water heater"
7B01
1
"Dual mode temperature external heat
source"
7B02
100 (
≙
10 °C)
"Start threshold external heat source"
7B03
300 (
≙
30 min)
"Start delay external heat source"
7B04
30 min
"Min. flow temperature mixer external
heat source ON"
7B05
0
"Min. runtime external heat source"
7B06
20 min
"Run-on time external heat source"
7B07
10 min
"Max. excess flow temp external heat
source"
7B0B
0
"Enable external heat gen. for central
heating"
7B0C
1
"Enable external heat source for DHW
heating"
7B0D
0
"Dual mode heat pump operation"
7B0E
1
"Shutdown limit, heat pump dual mode"
7B0F
–
500 (
≙
–
50 °C)
"Enable min. temp. maintenance for ext.
HS"
7B10
0
"Enable boiler water temperature sen-
sor"
7B11
1
Commissioning/service reports
Control parameters report
(cont.)
5516461
Appendix
Summary of Contents for BW 301.B06
Page 69: ...69 Fig 49 Maintenance Opening the casing door 5516461 Maintenance...
Page 76: ...76 Maintenance Condensation and moisture in the heat pump cont 5516461 Maintenance...
Page 79: ...79 Parts lists type BWC 301 B Parts not shown type BWC 301 B cont 5516461 Components...
Page 88: ...88 Parts lists type BWC 301 B Hydraulics type BWC 301 B cont 5516461 Components...
Page 91: ...91 Parts lists type BW 301 B Parts not shown type BW 301 B cont 5516461 Components...
Page 100: ...100 Parts lists type BW 301 B Hydraulics type BW 301 B cont 5516461 Components...
Page 103: ...103 Parts lists type BWS 301 B Parts not shown type BWS 301 B cont 5516461 Components...