124
Type BWC/BW/BWS
301.B06
301.B08
301.B10
301.B13
301.B17
Electrical values, heat pump
Rated voltage, compressor
3/N/PE 400 V/50 Hz
Rated current, compressor
A
4.8
6.2
7.4
9.7
13.0
Cos
φ
0.9
0.9
0.9
0.9
0.9
Starting current compressor with start-
ing current limiter (not for type
BWC/BW/BWS 301.B06)
A
25.0
14.0
20.0
22.0
25.0
Starting current, compressor with stal-
led armature
A
28.0
43.0
51.5
62.0
75.0
Compressor MCB/fuse protection
A
C16A
3-pole
B16A
3-pole
B16A
3-pole
B16A
3-pole
C20A
3-pole
Power consumption of factory-fitted
circulation pumps (type BWC only)
■
Primary pump
W
5 to 70
5 to 70
5 to 70
8 to 130
8 to 130
■
Energy efficiency index EEI of pri-
mary pump
≤
0.21
≤
0.21
≤
0.21
≤
0.23
≤
0.23
■
Secondary pump
W
5.7 to 87
5.7 to 87
5.7 to 87
5.7 to 87
5.7 to 87
■
Energy efficiency index EEI of sec-
ondary pump
≤
0.23
≤
0.23
≤
0.23
≤
0.23
≤
0.23
■
Circulation pump for cylinder heating W
3.8 to 70
3.8 to 70
3.8 to 70
3.8 to 70
3.8 to 70
■
Energy efficiency index EEI of circu-
lation pump for cylinder heating
≤
0.23
≤
0.23
≤
0.23
≤
0.23
≤
0.23
Protection class
I
I
I
I
I
Electrical values, control unit
(type BWC/BW only)
Rated voltage
1/N/PE 230 V/50 Hz
Fuse rating
B16A
Fuses
2 x 6.3 A H (slow)/250 V
Max. power consumption
W
1000
1000
1000
1000
1000
Power consumption in operation
W
5
5
5
5
5
Refrigerant circuit
Refrigerant
R410A
R410A
R410A
R410A
R410A
■
Refrigerant charge
kg
1.4
1.95
2.4
2.25
2.75
■
Global warming potential (GWP)
2088
2088
2088
2088
2088
■
CO
2
equivalent
t
2.9
4.1
5.0
4.7
5.7
Permissible operating pressure
■
Low pressure
bar
28
28
28
28
28
MPa
2.8
2.8
2.8
2.8
2.8
■
High pressure
bar
45
45
45
45
45
MPa
4.5
4.5
4.5
4.5
4.5
Compressor
Type
Hermetically sealed scroll
Oil in compressor
Type
Emkarate RL32 3MAF
Quantity of oil in compressor
l
0.74
1.24
1.24
1.24
1.89
Permiss. operating pressure
Primary circuit
bar
3
3
3
3
3
MPa
0.3
0.3
0.3
0.3
0.3
Secondary circuit
bar
3
3
3
3
3
MPa
0.3
0.3
0.3
0.3
0.3
Specification
Specification for brine/water heat pumps
(cont.)
5516461
Appendix
Summary of Contents for BW 301.B06
Page 69: ...69 Fig 49 Maintenance Opening the casing door 5516461 Maintenance...
Page 76: ...76 Maintenance Condensation and moisture in the heat pump cont 5516461 Maintenance...
Page 79: ...79 Parts lists type BWC 301 B Parts not shown type BWC 301 B cont 5516461 Components...
Page 88: ...88 Parts lists type BWC 301 B Hydraulics type BWC 301 B cont 5516461 Components...
Page 91: ...91 Parts lists type BW 301 B Parts not shown type BW 301 B cont 5516461 Components...
Page 100: ...100 Parts lists type BW 301 B Hydraulics type BW 301 B cont 5516461 Components...
Page 103: ...103 Parts lists type BWS 301 B Parts not shown type BWS 301 B cont 5516461 Components...