154
Type BW 301.A/BWS 301.A
06
08
10
13
17
Connections
Primary flow and return
G
1½
Heating flow and return
G
1½
Weight
Heat pump stage 1 (type
BW 301.A)
kg
113
117
129
135
148
Heat pump stage 2 (type
BWS 301.A)
kg
109
113
125
131
144
Sound power level
at
B0/W35 °C
(test with reference to DIN
EN ISO 9614-2)
dB(A)
40
41
41
41
42
Type WW 301.A/BWS 301.A in con-
junction with "conversion kit for
water/water heat pump"
06
08
10
13
17
Output data
to DIN EN 14511 (W10/
W35 °C, 5 K spread)
Rated heating output
kW
7.96
10.46
13.09
17.29
22.69
Cooling capacity
kW
6.73
8.87
11.09
14.74
19.09
Power consumption
kW
1.32
1.71
2.15
2.74
3.87
Coefficient of performance
ε
(COP)
6.03
6.11
6.10
6.31
5.87
Brine
(primary circuit)
Content
l
3.0
3.4
4.0
4.5
5.9
Min. flow rate (spread 4 K)
l/h
1530
2000
2570
3300
4450
Pressure drop (at min. flow
rate)
mbar
84
91
98
129
143
Max. flow temperature
°C
25
25
25
25
25
Min. flow temperature
°C
-5
-5
-5
-5
-5
Heating water
(secondary
circuit)
Content
l
2.4
2.9
3.4
4.0
5.2
Min. flow rate (spread 10 K) l/h
690
900
1170
1450
1990
Pressure drop (at min. flow
rate)
mbar
27
36
41
49
58
Max. flow temperature
°C
60
60
60
60
60
Specification
Specification
(cont.)
5600 161 GB