148
Parameter
Code
Delivered condi-
tion
Commis-
sioning
Ext. heat source
Enable external heat source
7B00
0
Priority ext. heat source/instant. heating
water heater
7B01
1
Dual mode temperature external heat
source
7B02
100 (
≙
10 °C)
Enable external heat source for DHW
heating
7B0D
0
DHW
Set DHW temperature
6000
500 (
≙
50 °C)
Min. DHW temperature
6005
100 (
≙
10 °C)
Max. DHW temperature
6006
600 (
≙
60 °C)
Hysteresis DHW temperature heat pump 6007
70 (
≙
7 K)
Hysteresis DHW temperature instant.
heating water heater
6008
100 (
≙
10 K)
Start optimisation for DHW heating
6009
0
Stop optimisation for DHW heating
600A
0
Set DHW temperature 2
600C
600 (
≙
60 °C)
Temperature sensor at bottom of DHW
cylinder
600E
0
Enable booster heaters for DHW heating 6014
0
Enable electric heaters for DHW heating 6015
1
Priority DHW heating with combi cylin-
der
6016
0
Start attempts for DHW after high pres-
sure shutdown
6017
1
Operating mode cylinder primary pump
6020
Never adjust!
Solar
Type solar control unit
7A00
0
Commissioning/service reports
Commissioning/service reports
(cont.)
5600 161 GB