65
"Function, output A1 at extension AM1"
Setting
Explanations
DHW circulation pump
33:0
Heating circuit pump, heating circuit without
mixer A1 (heating circuit 1)
33:1
Circulation pump for cylinder heating
33:2
"Function output, A2 at extension AM1"
Setting
Explanations
DHW circulation pump
34:0
Heating circuit pump, heating circuit without
mixer A1 (heating circuit 1)
34:1
Circulation pump for cylinder heating
34:2
"Extension EA1"
Setting
Explanations
Without
35:0
With
35:1
Value is set automatically upon detection
"Function, output 157 at extension EA1"
Setting
Explanations
Central fault message
36:0
Feed pump
36:1
DHW circulation pump
36:2
"Function, input DE1 at extension EA1"
Setting
Explanations
None
3A:0
Operating program changeover
3A:1
External demand with set flow temperature
3A:2
Set flow temperature setting: Parameter 9b
Internal circulation pump function: Parameter 3F
External blocking
3A:3
Internal circulation pump function: Parameter 3E
External blocking with fault message
3A:4
Internal circulation pump function: Parameter 3E
External fault message
3A:5
Fault message hook-up from external appliances
Brief operation, DHW circulation pump
(pushbutton function)
3A:6
Adjusting DHW circulation pump runtime: Parameter
3d
"Function, input DE2 at EA1 extension"
Setting
Explanations
None
3B:0
Operating program changeover
3B:1
External demand with set flow temperature
3B:2
Set flow temperature setting: parameter 9B
Internal circulation pump function: parameter 3F
External blocking
3B:3
Internal circulation pump function: parameter 3E
External blocking with fault message
3B:4
Internal circulation pump function: parameter 3E
External fault message
3B:5
Fault message hook-up from external devices
Brief operation, DHW circulation pump
(pushbutton function)
3B:6
DHW circulation pump runtime setting: parameter 3D
Parameter level 2
General
(cont.)
5778741
Parameter