118
Rated heating output range
at T
F
/T
R
50/30 °C
kW
1.9 - 13
1.9 - 19
2.6 - 26
at T
F
/T
R
80/60 °C
kW
1.7 - 12.1
1.7 - 17.6
2.4 - 24.1
for DHW heating
kW
1.7 - 16
1.7 - 17.2
2.4 - 23.7
Rated heating input range
kW
1.8 - 16.7
1.8 - 17.9
2.5 - 24.7
Rated voltage
V
230
230
230
Rated frequency
Hz
50
50
50
Rated current
A
6
6
6
Backup fuse
(power supply)
A
16
16
16
Power consumption
In the delivered condition
W
28
42
65
Maximum
W
80
86
95
Electronic temperature limiter
setting
°C
81
81
81
Temperature limiter setting
(fixed)
°C
100
100
100
Weight
kg
129
129
132
Supply values
relative to the max. load
Natural gas E
m
3
/h
1.77
1.89
2.61
Natural gas LL
m
3
/h
2.06
2.20
3.04
LPG P
kg/h
1.31
1.40
1.93
Permissible ambient temperature
■
During operation
°C
0 to +40
■
During storage and transport
°C
–
20 to +65
IP rating
IP X 4 to EN 60529
Protection class
I
Product ID
CE-0085CN0050
Note
The supply values are only for reference (e.g. in the
gas contract application) or for a supplementary, rough
estimate to check the volumetric settings. Due to fac-
tory settings, the gas pressure must not be altered
from these values. Reference: 15 °C, 1013 mbar
(101.3 kPa).
Specification
Specification
5778741