85
Instantaneous heating water heater
Parameters for
Instantaneous heating water heater
Setting
"Electr booster heater"
Ó
"Enable instantaneous heating water heater
7900"
"1"
"Electr booster heater"
, if applicable
Ó
"Enable instant. heating water heater for cen-
tral heating 7902"
"1"
"Electr booster heater"
Ó
"Output for instant. heating water heater at
power-OFF 790A"
"1"
: 3 kW
"2"
: 6 kW
"3"
: 9 kW
"DHW"
, if applicable
Ó
"Enable electric heaters for DHW heating
6015"
"1"
Swimming pool water heating
Parameters for swimming pool heating
Setting
"System definition"
Ó
"External extension 7010"
"1"
or
"3"
"System definition"
Ó
"Swimming pool 7008"
"1"
Ventilation
Ventilation unit parameters
Setting
"Ventilation"
Ó
"Vitovent enable 7D00"
"1"
Other enabling settings, if applicable:
"Ventilation"
Ó
■
"Enable preheater bank electric 7D01"
"1"
■
"Enable reheater bank hydraulic 7D02"
"1"
■
"Enable humidity sensor 7D05"
"1"
■
"Enable CO2 sensor 7D06"
"1"
If applicable, adjust values (subject to sizing):
"Ventilation"
Ó
■
"Set extract air temperature 7D08"
"100"
to
"300"
(
≙
10 to 30 °C)
■
"Flow rate reduced ventilation 7D0A"
"95"
up to
"7D0B"
minus
10 m
3
/h
Commissioning, inspection, maintenance
Further details regarding the individual steps
(cont.)
5546 699 GB