145
230 V appliances
Type AWT-AC
241.A04
241.A07
241.A10
241.A13
Heating output data
to EN 14511
(A2/W35)
Rated heating output
kW
3.0
5.6
7.7
10.6
Fan speed
rpm
870
650
650
650
Power consumption
kW
0.91
1.73
2.20
3.25
Coefficient of performance ε
(COP) in heating mode
3.27
3.24
3.50
3.26
Output control
kW
1.1 to 3.8 1.3 to 7.7 4.4 to 9.9
5.0 to
11.9
Heating output data
to EN 14511
(A7/W35, 5 K spread)
Rated heating output
kW
4.5
8.39
10.9
14.6
Fan speed
rpm
870
650
650
650
Air flow rate
m
3
/h
2090
3600
4210
4210
Power consumption
kW
0.97
1.96
2.36
3.40
Coefficient of performance ε
(COP) in heating mode
4.64
4.28
4.62
4.29
Output control
kW
1.2 to 5.3 1.8 to 9.5
5.0 to
14.0
5.0 to
16.1
Heating output data
to EN 14511
(A–7/W35)
Rated heating output
kW
3.20
6.60
8.72
9.14
Power consumption
kW
1.27
2.68
3.46
3.70
Coefficient of performance ε
(COP) in heating mode
2.58
2.49
2.55
2.47
Cooling capacity data
to EN 14511
(A35/W7, 5 K spread)
Rated cooling capacity
kW
3.2
6.2
7.4
9.1
Fan speed
rpm
870
650
650
650
Power consumption
kW
1.08
2.40
2.69
3.64
Energy efficiency ratio EER
2.96
2.58
2.75
2.50
Output control
kW
1.2 to 3.8 1.6 to 8.0 2.4 to 8.5
2.4 to
10.0
Cooling capacity data
to EN 14511
(A35/W18, 5 K spread)
Rated cooling capacity
kW
4.2
8.8
10.0
12.6
Fan speed
rpm
870
650
650
650
Power consumption
kW
1.13
2.63
2.80
4.20
Energy efficiency ratio EER
3.72
3.35
3.57
3.00
Specification
Specification
5546 699 GB
Service