16
8.
Press button
R
G
.
The system will be restarted.
Note
The setting parameters are displayed
each time the system is restarted.
1 Max. output (70-100 %)
The output setting is not limited.
The base load can also be set (CS
configuration).
2 Gas type (NG = natural gas or LPG
= liquid gas)
3 Installation height (LA or HA)
4 Temperature of temperature lim-
iter
5 Integral for minimum pause time
6 Cycle protection method
Note
Once the gas type has been converted,
the CO
2
values need to be checked for
full load and partial load and corrected if
necessary (see page 27 and 28).
Height adjustment
Note
To be able to adjust the settings the
burner must be on standby (Status "0",
Service "C").
Commissioning, inspection, maintenance
Further details regarding the individual steps
(cont.)
5794 780 GB