49
Clamps
Function
Explanation
553XD7
1: R+
2: R-
PE: Shield connection
Temperature sensor, heat ex-
changer defrosting, residual heat
brine outlet
Pt 1000
554XD1
1: R+
2: R-
PE: Shield connection
Temperature sensor, air/brine heat
exchanger air outlet
Pt 1000
554XD3
1: R+
2: R-
PE: Shield connection
Temperature sensor, air/brine heat
exchanger brine inlet
Pt 1000
554XD5
1: R+
2: R-
PE: Shield connection
Temperature sensor, air/brine heat
exchanger brine outlet
Pt 1000
554XD7
1: R+
2: R-
PE: Shield connection
Temperature sensor, heat ex-
changer defrosting, residual heat
water outlet
Pt 1000
555XD1
1: R+
2: R-
PE: Shield connection
Temperature sensor, air/brine heat
exchanger air inlet
Pt 1000
555XD3
1: R+
2: R-
PE: Shield connection
Temperature sensor, heat ex-
changer defrosting, residual heat
brine inlet
Pt 1000
555XD5
1: R+
2: R-
PE: Shield connection
Temperature sensor, heating cir-
cuit main flow
Pt 1000
555XD7
1: R+
2: R-
PE: Shield connection
DHW cylinder temperature sensor,
bottom
Pt 1000
556XD1
1: R+
2: R-
PE: Shield connection
DHW cylinder temperature sensor,
top
Pt 1000
556XD3
1: R+
2: R-
PE: Shield connection
Temperature sensor, DHW heat-
ing, high temperature mainte-
nance
Pt 1000
556XD5
1: R+
2: R-
PE: Shield connection
Temperature sensor, heating/cool-
ing circuit flow 1
Pt 1000
556XD7
1: R+
2: R-
PE: Shield connection
Temperature sensor, heating/cool-
ing circuit flow 2
Pt 1000
Installation procedure, heat pump
Electrical connections
(cont.)
5837251
Installation