45
Clamps
Function
Explanation
433XD1
1: Valve open
2: Valve closed
3: 24 VDC
4: 0 VDC
PE: Earth conductor
2-way motorised damper well/
groundwater, geothermal probes
Connection values:
■
Voltage: 24 VDC
■
Max. switching current: 5 A
434XD1
1: Valve open
2: Valve closed
3: 24 VDC
4: 0 VDC
PE: Earth conductor
2-way motorised damper, DHW
cylinder/heating water buffer cylin-
der
Connection values:
■
Voltage: 24 VDC
■
Max. switching current: 5 A
435XD1
1: Valve open
2: Valve closed
3: 24 VDC
4: 0 VDC
PE: Earth conductor
2-way motorised damper, residual
heat source
Connection values:
■
Voltage: 24 VDC
■
Max. switching current: 5 A
436XD1
1: Valve open
2: Valve closed
3: 24 VDC
4: 0 VDC
PE: Earth conductor
2-way motorised damper air/brine
heat exchanger residual heat
Connection values:
■
Voltage: 24 VDC
■
Max. switching current: 5 A
437XD1
1: Valve open
2: Valve closed
3: 24 VDC
4: 0 VDC
PE: Earth conductor
2-way motorised damper, heating
water buffer cylinder inlet
Connection values:
■
Voltage: 24 VDC
■
Max. switching current: 5 A
438XD1
1: Valve open
2: Valve closed
3: 24 VDC
4: 0 VDC
PE: Earth conductor
2-way motorised damper, air/brine
heat exchanger defrosting
Connection values:
■
Voltage: 24 VDC
■
Max. switching current: 5 A
439XD1
1: Valve open
2: Valve closed
3: 24 VDC
4: 0 VDC
PE: Earth conductor
2-way motorised damper, external
heat generator outlet
Connection values:
■
Voltage: 24 VDC
■
Max. switching current: 5 A
440XD1
1: Valve open
2: Valve closed
3: 24 VDC
4: 0 VDC
PE: Earth conductor
2-way motorised damper, heat ex-
changer defrosting, residual heat,
water
Connection values:
■
Voltage: 24 VDC
■
Max. switching current: 5 A
441XD1
1: Valve open
2: Valve closed
3: 24 VDC
4: 0 VDC
PE: Earth conductor
2-way motorised damper, DHW
heating inlet heat pump
Connection values:
■
Voltage: 24 VDC
■
Max. switching current: 5 A
Installation procedure, heat pump
Electrical connections
(cont.)
5837251
Installation