PlasmaView VHD Service Remote Control
Vidikron PlasmaView VP-6000 VHD Owner’s Operating Manual
A-3
A.2
Service/Setup Menu
For the vast majority of installations, the VHD Controller remote control gives you all the
control you need over display quality settings. However, there are two settings internal to
the PlasmaView VHD that can improve the displayed image quality on INPUT 1: VID NR (noise
reduction) and MPEG FILTER. These settings can be found in the Setup Menu, shown in
Figure A-2.
Figure A-2. PlasmaView VHD Setup Menu
Video NR (Noise Reduction)
To apply Digital Noise Reduction (DNR) to the input signal, select Video NR from the Set-Up
menu. Noise reduction is useful for improving the signal-to-noise ratio of video signals.
To change the Noise Reduction setting on INPUT 1:
1.
Press
1
to switch to PlasmaView VHD INPUT 1.
2.
Press
MENU
on the PlasmaView VHD Service Remote Control.
3.
Press
or
to select SETUP.
4.
Press
to select VIDEO NR, then press
SET
.
5.
Press
or
to select the desired amount of noise reduction (OFF, LOW, MIDDLE or
HIGH).
6.
Press
SET
to confirm your selection.
INPUT 2
PLASMAVIEW
SCREEN
SET-UP
OPTION
PICTURE
SET
SET
EXIT
MENU
: MIDDLE
: OFF
: VID NR1
: LOW
: ON
: OFF
: RGB
: 720p
COLOR TEMP.
AUTO OFF
VID NR
MPEG FILTER
CHROMA EE
CINEMA MODE
COLOR SPACE
DVI SET UP
SIGNAL