Maintenance and Troubleshooting
Vidikron PlasmaView VP-6000 VHD Owner’s Operating Manual
49
PRE
L
IMINAR
Y
Colors in the image are
swapped; for example, reds
appear blue or vice versa.
•
The Red/Pr, Green/Y or
Blue/Pb outputs from the
source are connected to the
wrong inputs on the VHD
Controller.
•
The Red, Green or Blue
(analog) outputs from the
VHD Controller are
connected to the wrong
inputs on the PlasmaView
VHD.
•
Ensure that the source
outputs are connected to
the correct VHD Controller
input.
•
Ensure that the VHD
Controller outputs are
connected to the correct
inputs on the PlasmaView
VHD.
RGB-HD images appear
“noisy.”
•
Clock and Phase settings
need adjustment.
•
Adjust Clock and Phase
settings (refer to
ISF Night -
Display Color
on page 41).
“Out of range” appears
on-screen.
•
The resolution and
frequency of the video card
in the computer are not
compatible with the
PlasmaView VHD.
•
Select a compatible
resolution and vertical
frequency (refer to
Computer/Video Signal
Compatibility
on page 60).
The image is too large or too
small.
•
Image size needs adjusting.
•
Adjust the image size (refer
to
Input Position
on
page 39).
Table 5-1. Troubleshooting Chart (continued)
Symptom
Possible Cause(s)
Solution