66550062-EN - V6.0 - 31/10/21
- 13 -
IPVK/6296 Series IP videokit
IPVK/6296 Series - Installation handbook
CONNECTION TERMINALS SIGNALS
SW2
Relay 2 command signal (active low)
SW1
Relay 1 command signal (active low)
NC3
Relay 3 normally closed contact
Max
24Vac/dc
3A
NO3
Relay 3 normally open contact
C3
Relay 3 common contact
NC2
Relay 2 normally closed contact
NO2
Relay 2 normally open contact
C2
Relay 2 common contact
NC1
Relay 1 normally closed contact
NO1
Relay 1 normally open contact
C1
Relay 1 common contact
–
12/24Vac/dc power input
+
CLEANING OF THE PLATE
Use a clean and soft cloth. Use moderate warm water or non-ag-
gressive cleansers.
Do not use:
• abrasive liquids;
• chlorine-based liquids;
• metal cleaning products.
TECHNICAL SPECIFICATION
Power Supply:
12/24 Vac/dc – 2VA
Power Consumption:
Stand-by: 20mA
Operating: 70mA
Working Temperature:
-20 +60° C
Art. 4901
Digital codelock module