Instruc
tions manual - English - EN
19
MNVCUPTMAXB_1511_EN
8 Installation
Never, under any circumstances, make
any changes or connections that are not
shown in this handbook. Failure to follow
the connection instructions that are given
in the handbook may create serious safety
hazards for people and for the installation.
Do not change the wiring in the product
as it is supplied to you. Failure to follow
this instruction may create serious safety
hazards for people and for the installation,
and will also invalidate the guarantee.
If using the washer kit, the nozzle support
should be installed before positioning
the pan & tilt and the wiring. For further
explanations see the specific handbook for
the kit.
Fig.
21
Inside the bottom cover there is a desiccant
bag that is used to prevent moisture
formation in the base and near the
connector boards. Remove the bag before
installation.
8.1 Connecting the cables to the
base
Insert the cables into the cable glands holding the
base at about 20cm from the support. Tighten the
cable glands. The cable glands are suitable for cables
with a diameter between 5mm and 10 mm.
Fig.
22
Pay attention to the fixing. Tightening
torque: 5Nm.
For cables diameter from 3mm to 7mm use
the supplied gaskets.
Fig.
23