8.14.4 DIP3 configuration
When the switch rocker is up it represents
the value 1 (ON). When the dip-switch
rocker is down it represents the value 0
(OFF).
Fig.
70
8.14.4.1 Address configuration
Switches from 1 to 8 are used to configure the unit
address (from 1 to 255).
Binary code is used to select the address (A Appendix
8.14.4.2 Setting of the serial communication
lines
The product is supplied with two RS-485 serial
communication lines.
Switches 10 and 9 are used to configure the serial
lines.
DIP3 CONFIGURATION
Description
SW 10
SW 9
One-way communication on RS-485-1 line
OFF
OFF
Full-duplex communication according to
standard RS-422.
OFF
ON
Connection of several cascade devices.
Signal is regenerated by each unit.
ON
OFF
Two-way communication, half-duplex, on
RS-485-1 line.
ON
ON
Tab.
15
For further information refer to the relative
chapter (8.14.6 Installation examples, page
8.14.5 DIP4 configuration
This DIP is set following the inverse
procedure compared to those previously
performed. When the switch rocker is up
it represents the value 0 (OFF). When the
dip-switch rocker is down it represents the
value 1 (ON).
The board has two switches used to configure the
serial lines terminations (120 Ohm).
Fig.
71
Every unit that is situated at the end of a line must be
terminated using the appropriate switch in order to
prevent signal reflection and distortion.
Switches 1 and 2 terminate serial lines RS-485-1 and
RS-485-2 respectively.
DIP4 CONFIGURATION
Serial line
SW 2 SW 1 Description
RS-485-1 line
–
ON
Terminated
–
OFF
Not terminated
RS-485-2 line
ON
–
Terminated
OFF
–
Not terminated
Tab.
16