EN - English - I
nstruc
tions manual
40
MNVCUPTMAXB_1511_EN
10.1.1.4 How to change the numeric fields
Move the cursor to the parameter to be changed and
confirm.
EDIT PRESET
------------------------
1 NR. : 1
2 ENAB.: N
3>PAN : + 0.00
4 TILT : - 40.00
5 SPEED: 20.00
6 PAUSE: 5
7 TEXT : PRESET 001
8 GO TO PRESET?
Fig.
83
The first digit in the numeric field to be changed will
flash and the last line of the display will show the
accepted limits for the field. Move in the field (left
and right) and change the sign or the numeric value
(up and down).
EDIT PRESET
------------------------
1 NR. : 1
2 ENAB.: N
3>PAN : +000.00
4 TILT : - 40.00
5 SPEED: 20.00
6 PAUSE: 5
7 TEXT : PRESET 001
8 GO TO PRESET?
min:-180.00 max:+179.99
Fig.
84
After making the change, confirm. The cursor returns
to the left and the modified digit will stop flashing.
The field will be forced to the minimum or maximum
value permitted if an unexpected value is entered.
10.1.1.5 How to change text
Move the cursor to the parameter to be changed and
confirm.
EDIT ZONE
------------------------
1 NR : 1
2 START:+ 0.00
3 STOP :+ 0.00
4>TEXT :TXT AREA1
Fig.
85
The text editing display will open. The arrow symbol
is placed under the character that can be modified,
whilst cursor > is positioned on the left of the
selected character.
EDIT TEXT: AREA
------------------------
Text: TEXT AREA1
↑
>A B C D E F G ERASE
H I J K L M N SAVE
O P Q R S T U EXIT
V W X Y Z 0 1 abc
2 3 4 5 6 7 8
9 : ; . , ? !
‘ + - * / = “
< > SPACE ← →
Fig.
86