3.4.16.1
Defining the time event
The event is defined in the same way for each category and at each stage the keys to be pressed are
shown at the bottom of the screen:
•
select the line to be modified with
/
or with the joystick (there is always at least one empty
event in the list) and if necessary press
to erase it after selection
•
press
to request modification or insertion of a new event
•
insert the
KEYBOARD/RELAY/ALARM CONTACT
number
•
define the operation to be carried out (it may be
OPEN/CLOSE
or
ENABLE/DISABLE
depending on the
category)
•
insert the period during which the event is to be activated:
1. only during the open period (the time of activation will be requested)
2. only during the closed period (the time of activation will be requested)
3. always (the time of activation will be requested )
4. at the beginning of every open period
5. at the beginning of every closed period
•
if requested insert the event activation time.
Events of type 1/2/3, for which the time of activation is requested, are active as from the pre-set time
only
if the indicated activation period is correct.
For example, suppose that we want to switch on a light at 17:30
only on working days, then switch it off 5 minutes later:
1. we define the working days with the open period from 8:00 to 17:40
2. we define a Time Relay Event to close relay 1 during activation period 1 (only during the open
period) at 17:30
3. we define a Time Relay Event to open relay 1 during activation period 1 (only during the open
period) at 17:35
This type of event setup will switch the light on only on the days in which 17:30 and 17:35 fall within the
open period, and not on the days when these times fall in the closed period, on Sundays for example.
During insertion the time events are ordered automatically.
Notes
The event list may refer to objects that are not available (unconnected keyboards, relays operated by alarms and non-
used alarm contacts). In this case, even if the event is defined it will be ignored. The event indication is preceded by a
'?' mark to show there is something wrong.
•
3. Setup
Page 24/66
MNVCSM328A_1511_EN
Summary of Contents for sm328a
Page 3: ...OPERATING INSTRUCTIONS ...
Page 4: ......
Page 70: ... 8 Configuration software Page 66 66 MNVCSM328A_1511_EN ...
Page 71: ...MANUALE D USO ...
Page 72: ......
Page 138: ... 8 Software di configurazione Pag 66 66 MNVCSM328A_1511_IT ...
Page 139: ...MANUEL D INSTRUCTIONS ...
Page 140: ......
Page 207: ...BEDIENUNGSANWEISUNG ...
Page 208: ......
Page 275: ...РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ ...
Page 276: ......
Page 342: ... 8 Конфигурация программного обеспечения Pag 66 66 MNVCSM328A_1511_RU ...
Page 343: ......