5.5.2 Step 2: Other settings
Parellel operation: the remaining settings are not relevant (na) for slaves.
Three Phase or split phase: some of the remaining settings are not relevant for
followers (L2, L3). These settings are imposed on the whole system by the leader
L1. If a setting is irrelevant for L2, L3 devices, this is mentioned explicitly.
ds8-ds7: Setting charging voltages (not relevant for L2, L3)
ds8-ds7
Absorption
voltage
Float
oltage
Storage
voltage
Suitable for
off off
14.1
28.2
56.4
13.8
27.6
55.2
13.2
26.4
52.8
Gel Victron Long Life (OPzV)
Gel Exide A600 (OPzV)
Gel MK battery
off on
14.4
28.8
57.6
13.8
27.6
55.2
13.2
26.4
52.8
Gel Victron Deep Discharge
Gel Exide A200
AGM Victron Deep Discharge
Stationary tubular plate (OPzS)
on off
14.7
29.4
58.8
13.8
27.6
55.2
13.2
26.4
52.8
AGM Victron Deep Discharge
Tubular plate traction batteries
in semi-float mode
AGM spiral cell
on on
15.0
30.0
60.0
13.8
27.6
55.2
13.2
26.4
52.8
Tubular plate traction batteries
in cyclic mode
ds6: absorption time 8 or 4 hours
(na for L2, L3) on = 8 hours
off = 4 hours
ds5: adaptive charging characteristic
(na for L2, L3) on = active
off = inactive
(inactive = fixed absorption time)
ds4: dynamic current limiter
on = active
off = inactive
ds3: UPS function
on = active
off = inactive
ds2: converter voltage
on = 120V
off = 115V
ds1: converter frequency
(na for L2, L3) on = 50Hz
off = 60Hz
(the wide input frequency range (45-55Hz) is 'on' by default)
Summary of Contents for MultiPlus 12/3000/120 - 50
Page 1: ...Manual EN Appendix MultiPlus 12 3000 120 50 120V 24 3000 70 50 120V ...
Page 2: ......
Page 4: ......
Page 50: ......
Page 51: ...EN Appendix www victronenergy com APPENDIX A Overview connections B H I J F E G A C K L ...
Page 53: ...EN Appendix www victronenergy com APPENDIX B Block diagram See table in section 4 2 ...
Page 58: ...APPENDIX G Dimensions ...
Page 59: ...EN Appendix www victronenergy com ...
Page 60: ......
Page 61: ...www victronenergy com ...