OPERATION
4-16
Manual No. 0-5133
ULTRA-CUT 200
4.11 Power Supply Status Codes
On start-up and during operation, the power supply control circuitry performs various tests. If the circuitry
detects a condition requiring operator attention, the status indicator on the control panel flashes a 2-part code
to indicate a code group and then a particular condition within the group. After 4 seconds, the sequence
repeats.
Example: Indicator flashes 4 times; the condition is in group 4. After a 1.2 second delay, the indicator blinks
3 times; the condition code is 4-3, indicating that the coolant is overheating. After a 4-second delay, the
indicator repeats the sequence until the condition is corrected.
Some conditions can be active indefinitely, while others are momentary. The power supply latches momentary
conditions; some momentary conditions can shut down the system. The indicator may show multiple condi-
tions in sequence; it is important to recognize all possible conditions that may be displayed.
Note
These codes are for systems with Firmware versions 2.4 or later. If your system’s Firmware is a prior version,
contact your distributor for updates.
Code
Message
Remedy / Comments
1-1
Plasma Disabled or
Missing AC Input Phase
Plasma Enable Off ; External Disable / E-Stop Activated or CCM TB1-
1&2 jumper missing; Control cable to DMC not connected; Missing
AC Phase.
1-2
Pilot Ignition Failure
Pilot did not start within 15 seconds. Ensure process loaded agrees
with torch parts installed; Torch consumable parts worn; Defective
Arc Starter. Defective chopper (100-300A unit); Defective #2 inverter
(400A unit).
1-3
Lost Pilot
Pilot went out while CNC Start active Ensure process loaded agrees
with torch parts installed; If custom process cut current too low or
preflow pressure too high. Torch consumable parts worn
1-4
Transfer Lost
Arc was transferred to work for more than 50 ms and then went out
while CNC Start still active. Standoff too high; Ensure process
loaded agrees with torch parts installed; If custom process current
set too low or wrong plasma pressure.
1-5
Off the Plate
Function not currently enabled
1-6
Pilot Timeout, no
Transfer
Must transfer from Pilot to Cutting Arc in 85 ms. (SW8-1 OFF) or 3
sec. (SW8-1 ON). Standoff too high or void in work under torch;
Wrong cut process selected resulting in: Pilot current too low for
consumables; Preflow pressure too low.
1-7
Reserved
No information available; Contact customer service
1-8
Possible Shorted Torch
Tip voltage too close to electrode voltage. Plasma supply pressure
too low; Leak in Plasma hose to torch; Ensure process loaded
agrees with torch parts installed; If custom process, plasma
pressure may be too low or cut current too high. Torch consumable
parts worn; Shorted torch body
1-9
Part Process not
configured
CNC Start applied without a process loaded. Select process and send
to plasma system
1-10
Device Locked
Process loading, wait until finished
Group 1 -- Plasma Process
CCM Status Code
Summary of Contents for ULTRA-CUT 200
Page 4: ...Thispageintentionallyblank...
Page 8: ...NOTE Section 8 Torch operation is provided separately...
Page 16: ...ULTRA CUT 200 1 8 Manual 0 5133...
Page 26: ...Manual No 0 5133 Ultra Cut 200 2 10 SPECIFICATIONS This Page Intentionally Blank...
Page 53: ...Manual No 0 5133 3 27 INSTALLATION ULTRA CUT 200 Art A 09151 After...
Page 128: ...Manual No 0 5133 Ultra Cut 200 6 30 Power Supply Parts List ULTRA CUT 200 Intentionally Blank...
Page 167: ...This Page Intentionally Blank...