3-17
INSTALLATION
ULTRA-CUT 200
CAUTION
Printed circuit boards in the Command - Control Module are static - sensitive. Discharge any built-up static
charges in your body or surroundings before touching the printed circuit boards.
SW-6: OK-to-Move: Contact closure, 120VAC @ 1A (Factory default setting) or
DC Volts (16-18vdc@ up to 100 ma.)
SW-11: Analog Current Control. B = from Gas Control (Factory default setting) or A = Remote Analog Source.
Position A requires that SW-8-2 be ON.
SW-12-1/2/3/4: Divided Arc signal
All = OFF = 50:1 (Factory default setting)
1 = ON = 16.6:1
2 = ON = 30:1
3 = ON = 40:1
4 = ON = 25:1
Art # A-09167
Only 1 on at a time.
SW13: Auto Gas Switch positions
SW13 (Note positions 3-4 are not yet used)
1
2
3
4
SW11
SW13
SW6
SW12