Manual No. 0-5133 Ultra-Cut 200
5-1
MAINTENANCE
ULTRA-CUT 200
SECTION 5: MAINTENANCE
5.01 Periodic Checks
Perform the following checks periodically to ensure proper system performance.
Power Supply Maintenance Schedule
Daily
Check coolant level; add coolant as needed.
Check gas hose connections and pressures.
Monthly
Check cooling fan and radiator; clean as needed.
Check gas hoses for cracks, leaks, or abrasion.
Replace as needed.
Check all electrical connections
for cracks or abrasion. Replace as needed.
Six M onths
Clean or replace external coolant filter.
Clean coolant tank.
Vacuum out any dust buildup inside power supply.
Check internal coolant filter
5.02 External Coolant Filter Cleaning Procedure
Periodic cleaning of the coolant filter ensures maximum coolant flow efficiency. Poor coolant flow causes ineffi-
cient torch parts cooling with consequent faster consumable wear.
Clean the coolant filter as follows:
1. Disconnect the system from main input power.
Filter Screen
Filter Holder
Art # A-04811
2. Unscrew and remove the filter bowl by hand. Be sure to keep the O-ring.
3. Remove and clean the filter. Re-install the bowl, tightening it
by hand.
Be sure the O-ring is in place.
4. Turn the system on and check for leaks.
Summary of Contents for ULTRA-CUT 200
Page 4: ...Thispageintentionallyblank...
Page 8: ...NOTE Section 8 Torch operation is provided separately...
Page 16: ...ULTRA CUT 200 1 8 Manual 0 5133...
Page 26: ...Manual No 0 5133 Ultra Cut 200 2 10 SPECIFICATIONS This Page Intentionally Blank...
Page 53: ...Manual No 0 5133 3 27 INSTALLATION ULTRA CUT 200 Art A 09151 After...
Page 128: ...Manual No 0 5133 Ultra Cut 200 6 30 Power Supply Parts List ULTRA CUT 200 Intentionally Blank...
Page 167: ...This Page Intentionally Blank...