Code Message
Cause/Remedy
6-1
Valve open
Check for open connection; Replace valve.
6-2
DPC inlet Supply
pressure low
Raise plasma inlet pressure; check for DMC valve not open; restriction in gas
supply/hoses.
6-3
Outlet pressure too low
Valve full open but pressure still too low. Leak in plasma hose to torch; Defective control
valve (V4); Defective pressure sensor (PS6); DPC Control PCB
6-4
Outlet pressure low
Tracking error. Leak in plasma hose to torch; Defective control valve (V4); Defective
pressure sensor (PS6); DPC Control PCB
6-5
Outlet pressure Too
high
Valve at minimum setting but pressure still too high. Restriction in plasma hose to torch;
torch or DPC manifold; Defective control valve (V4); Defective pressure sensor (PS6); DPC
Control PCB
6-6
Outlet pressure high
Tracking error. Restriction in plasma hose; torch or DPC manifold; Defective control valve
(V4); Defective pressure sensor (PS6); DPC Control PCB
7-1
Valve open
Check for open connection; Replace valve.
7-2
DPC inlet Supply
pressure low
Raise plasma inlet pressure; check for DMC valve not open; restriction in gas
supply/hoses.
7-3
Outlet pressure too low
Valve full open but pressure still too low. Leak in plasma hose to torch; defective control
valve; defective pressure sensor (PS6); DPC Control PCB
7-4
Outlet pressure low
Tracking error. Leak in plasma hose to torch; defective control valve; defective pressure
sensor (PS6); DPC Control PCB
7-5
Outlet pressure Too
high
Valve at minimum setting but pressure still too high. Restriction in plasma hose, torch,
DPC manifold; defective control valve; defective pressure sensor (PS6); DPC Control PCB
7-6
Outlet pressure high
Tracking error. Restriction in plasma hose, torch, DPC manifold; defective control valve;
defective pressure sensor (PS6); DPC Control PCB
8-1
Valve open
Check for open connection; Replace valve.
8-2
DPC inlet Supply
pressure low
Raise plasma inlet pressure; check for DMC valve not open; restriction in gas
supply/hoses.
8-3
Outlet pressure too low
Valve full open but pressure still too low. Leak in plasma hose to torch; defective control
valve; defective pressure sensor (PS5); DPC Control PCB
8-4
Outlet pressure low
Tracking error. Leak in plasma hose to torch; defective control valve; defective pressure
sensor (PS5); DPC Control PCB
8-5
Outlet pressure Too
high
Valve at minimum setting but pressure still too high. Restriction in plasma hose, torch,
DPC manifold; defective control valve; defective pressure sensor (PS5); DPC Control PCB
8-6
Outlet pressure high
Tracking error. Restriction in plasma hose, torch, DPC manifold; defective control valve;
defective pressure sensor (PS5); DPC Control PCB
9-1
Valve open
Check for open connection; Replace valve.
9-2
DPC inlet Supply
pressure low
Raise plasma inlet pressure; check for DMC valve not open; restriction in gas
supply/hoses.
9-3
Outlet flow too low
Valve full on but pressure still too low. Leak in shield hose to torch; Defective control valve
(V2); Defective pressure sensor (PS5) or flow sensor (FS-1) if equiped; DPC Control PCB
9-4
Outlet flow low
Tracking error, outlet pressure too low. Leak in shield hose to torc; Defective control valve
(V2). Defective pressure sensor (PS5) or flow sensor (FS-1) if equiped; DPC Control PCB
9-5
Outlet flow Too high
Valve set to minimum but valve outlet pressure still too high. Mineral build up or other
restriction in control valve (V2), DPC manifold, shield hose or torch; Defective control valve
(V2)/ Defective pressure sensor (PS5) or flow sensor (FS-1) if equiped; DPC Control PCB
9-6
Outlet flow high
Tracking error, outlet pressure too high. Mineral build up or other restriction in control
valve (V2), DPC manufold, shield hose or torch; Defective control valve (V2); Defective
pressure sensor (PS5) or flow sensor (FS-1) if equiped; DPC Control PCB
Group 9 - Shield H2O Proportional Valve (V2)
DPC Status Code Key
Group 6 - Plasma Low Proportional Valve (V4)
Group 7 - Pilot Proportional Valve (V3)
Group 8 - Shield Gas Proportional Valve (V1)
Summary of Contents for ULTRA-CUT 200
Page 4: ...Thispageintentionallyblank...
Page 8: ...NOTE Section 8 Torch operation is provided separately...
Page 16: ...ULTRA CUT 200 1 8 Manual 0 5133...
Page 26: ...Manual No 0 5133 Ultra Cut 200 2 10 SPECIFICATIONS This Page Intentionally Blank...
Page 53: ...Manual No 0 5133 3 27 INSTALLATION ULTRA CUT 200 Art A 09151 After...
Page 128: ...Manual No 0 5133 Ultra Cut 200 6 30 Power Supply Parts List ULTRA CUT 200 Intentionally Blank...
Page 167: ...This Page Intentionally Blank...