4.
Hold pump so that fill plug end is ABOVE
the hydraulic power cylinder . This will prevent
siphoning of oil from the hydraulic power
cylinder through pump .
5.
Check fluid level . Add hydraulic jack oil to
proper level as required . On models without dip
stick, remove cap; oil should be approximately
1/2” to 1” from the end .
AIR BLEEDING
1.
To bleed air from the system, hold the entire
pump above the hydraulic power cylinder . Close
the pump release valve by turning clockwise .
Open fill plug one full turn .
2.
Pump the pump handle several strokes to
build pressure .
3.
Open release valve by turning
counterclockwise and allow air to escape .
4.
Repeat steps 1-3 several times to bleed all
the air from the system .
5.
Check oil level and add oil if necessary .
TM-VE416FS/FSD_25