![Victaulic VE416FS Operating And Maintenance Instruction Manual Download Page 26](http://html1.mh-extra.com/html/victaulic/ve416fs/ve416fs_operating-and-maintenance-instruction-manual_1013577026.webp)
3.
Grease main shaft bearings at fittings
provided as shown .
VE416FSD ONLY
LUBRICATION – MONTHLY
1.
Lubricate drive gear as shown with a spray
type heavy duty open gear lubricant (Lubriplate
Gear Shield Extra Heavy or equivalent) . To
thoroughly lubricate, plug tool into proper outlet
and jog drive gear around to several locations
by depressing foot switch momentarily and then
lubricating the gear at each position .
VE416FS AND VE416FSD HYDRAULIC
SYSTEMS
The level of hydraulic fluid in the pump should
be checked before operation and
must
be
checked semi-annually or if pumping feels
spongy .
FILLING AND CHECKING
1.
Open pump release valve fully by turning
counterclockwise .
2.
Remove pump and mounting table from side
of tool .
3.
Loosen, but do not remove, the hydraulic fill
plug/dipstick at the back end of the pump .
TM-VE416FS/FSD_24
TM-VE416FS/FSD
OPERATING AND MAINTENANCE INSTRUCTIONS MANUAL
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.
REV_A