6.
Close hand pump valve .
7.
Pump upper roll down into firm contact with
pipe .
8.
Remove the guard setting pad from its
storage hook beneath the pump support . Hold
the guard setting pad firmly down against the
pipe and push it under the adjustable guards
flush against the red plate .
9.
Loosen the wing nuts and adjust each guard
to conform to and lightly pinch the pad against
the pipe . Tighten wing nuts to secure guards in
position .
10.
Remove the guard setting pad . Store the
pad back on the hook provided under pump
base .
PIPE STABILIZER ADJUSTMENT
The Series 416 Pipe Stabilizer is designed to
prevent pipe sway on 6” through 16” nominal
IPS pipe sizes . This applies to short as well as
long pipe . Once the stabilizer is adjusted for a
selected pipe size and wall, it does not require
further adjustment on that size . Pipe of the
same size and wall may be moved in and out of
the tool without retracting stabilizer .
WARNING
• Turn off power until instructed otherwise.
Accidental start up of tool may result in
serious injury.