15.
Open hydraulic release valve to release
pipe . Remove pipe from tool .
NOTICE
• Groove diameter should be correct for the
diameter and wall thickness of pipe for
which it was set under Groove Diameter
Stop Adjustment. Groove diameter should
be checked periodically and adjusted as
necessary to assure grooves are within
specification.
ROLL CHANGING
WARNING
• Always turn off power or unplug tool
before making any tool adjustments.
Accidental start-up of tool may result in
serious injury.
ROLL REMOVAL 4 - 16”
Vic-Easy Series 416 roll grooving tools
are designed for fast, easy grooving . Rolls
accommodate several pipe sizes (refer to Tool
Rating and Roll Selection on pages 29 and 30)
eliminating the need for frequent roll changes .
When a different size range is encountered or
special grooving styles are required, the grooving
rolls must be changed and Pre-Operation
Adjustments re-performed . Also, different pipe
materials may require that the rolls be changed .
Refer to Tool Rating and Roll Selection, pages
29 and 30, for proper roll selection .
UPPER ROLL
1.
Open hand pump release valve (turn knob
counterclockwise) which will move slide to the
full open position .
2.
With a wrench, loosen and remove upper roll
bolt and retaining plate as shown . Place on a
clean surface .
3.
Slide the upper roll off the upper shaft as
shown and store in the roll tote box supplied .
TM-VE416FS/FSD_20
TM-VE416FS/FSD
OPERATING AND MAINTENANCE INSTRUCTIONS MANUAL
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.
REV_A