VD520 Series Inverter User Manual Parameter Description
- 167 -
FC-17
Simple PLC Power
Failure Retentive
Selection
Unit’s digit: power failure retentive
selection
0: Non-retentive at power failure
1: Retentive at power failure
Ten’s digit: stop retentive selection
0: Non-retentive at stop
1: Retentive at stop
0x00
○
PLC power failure retentive refers to the running stage and running frequency of PLC before the
power failure retentive, the next time power on from memory stage to continue running. Selection non
retentive, then each time power on to restart PLC process.
PLC stop retentive is records the running stage and running frequency of the previous PLC when
power off, the next time running from memory stage to continue running. Selection non retentive, then
each time start to restart PLC process.
FC-18
Run Time of Simple PLC
Reference 0
0.0s (h)~6553.5s (h)
0.0s (h)
○
FC-19
Acceleration /
Deceleration Time
Selection of Simple PLC
Reference 0
0~3
0
○
FC-20
Run Time of Simple PLC
Reference 1
0.0s (h)~6553.5s (h)
0.0s (h)
○
FC-21
Acceleration /
Deceleration Time
Selection of Simple PLC
Reference 1
0~3
0
○
FC-22
Run Time of Simple PLC
Reference 2
0.0s (h)~6553.5s (h)
0.0s (h)
○
FC-23
Acceleration /
Deceleration Time
Selection of Simple PLC
Reference 2
0~3
0
○
FC-24
Run Time of Simple PLC
Reference 3
0.0s (h)~6553.5s (h)
0.0s (h)
○
FC-25
Acceleration /
Deceleration Time
Selection of Simple PLC
Reference 3
0~3
0
○
FC-26
Run Time of Simple PLC
Reference 4
0.0s (h)~6553.5s (h)
0.0s (h)
○
FC-27
Acceleration /
Deceleration Time
Selection of Simple PLC
Reference 4
0~3
0
○
FC-28
Run Time of Simple PLC
Reference 5
0.0s (h)~6553.5s (h)
0.0s (h)
○