How to set inline relieve valve
.
•
The in line relief valve is factory set to open at 90 bar
(1300 PSI) at 50 l/min (13,2 gallon)
•
For resetting the valve;
A
. Fit a pressure gauge between hose and valve
Lower the machine with 50 l/min. (13,2 gallon)
B.
Loosen the counter nut
C.
Set pressure to 90bar by turning bolt; after
setting retighten the counter nut.