Testing
5 -9
5.2.6.B
Diagnostics Function Window
Selecting Diagnostics from the Maintenance sub-menu will display the Diagnostics
Function Window. The Diagnostics Function Window provides control for generating test
signals, with specific power and frequency parameters.
Fig. 5-5 Diagnostics Function Window
Control Component
Description
Mode
Drop down selections:
OFF - Diagnostics output disabled and simulation is allowed.
CW - Diagnostics output enabled, output is CW and simulation
is locked.
MODULATED - Diagnostics output enabled, output is
modulated GPS signal and simulation is locked.
Frequency
Drop down selections: 1176.45 MHz, 1207.14 MHz, 1227.60
MHz, 1278.75 MHz or 1575.42 MHz.
Amplitude
Numeric pad: Power in dBm. Range -93 dBm to +155 dBm
DIRECT or -68 dBm to -130 dBm COUPLER
Doppler Error
Numeric Pad: +/- 5000Hz in 1 Hz increments.
EXT REF OUT
Drop down selections: ON or OFF.
Reference Sources
Drop down selections: INT or EXT.
LOG AMP
Displays the output from the internal up convertor module.
Displayed in dB.
Read
Reads the output from the internal up convertor module.
PLL Lock Status
Indicates the state of the LO, 800 Mhz, EXT. REF and EXT.
REF DET. ON (Green) indicates locked condition, OFF (Gray)
indicates unlocked condition.
Summary of Contents for 87339
Page 1: ...GPSG 1000 GPS Galileo Positional Simulator Operation Manual...
Page 4: ...ii THIS PAGE INTENTIONALLY LEFT BLANK...
Page 6: ...iv THIS PAGE INTENTIONALLY LEFT BLANK...
Page 12: ...x THIS PAGE INTENTIONALLY LEFT BLANK...
Page 24: ...iv THIS PAGE INTENTIONALLY LEFT BLANK...
Page 26: ...ii THIS PAGE INTENTIONALLY LEFT BLANK...
Page 117: ...Testing 5 18 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 157: ...Principals of Operation 7 6 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 161: ...A 4 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 167: ...B 6 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 189: ...F 2 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 191: ...G 2 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 193: ...H 2 THIS PAGE INTENTIONALLY LEFT BLANK...