Chapter 4 - Maintenance
4.3 Corrosion Protection
Perform the following procedures after completing the installation and every
12 months thereafter.
NOTE
Pressurization of transmit waveguide runs and feed
components should be maintained to prevent moisture from
entering the system. Receive only pressurization is optional.
1. Evaluate the corrosion protection on the mount, actuators, and related hardware.
If the protective finish is damaged, clean with a wire brush, remove all rust, and
apply a coat of Rust-Oleum (or equivalent) spray-on cold galvanizing
compound.
2. Evaluate the corrosion protection on the reflector surface, spars, feed,
potentiometer brackets and related hardware. If the paint is scratched, chipped,
beginning to flake, or just wearing thin, lightly sand with 320 grit (or finer)
sandpaper and apply a coat of Rust-Oleum (or equivalent) primer and semi-
gloss white paint.
42S199F 4-5