Dear Customer,
Thank you for purchasing the pyrolytic boiler Hefaistos P1 and thus showing your confidence in the
company VIADRUS a.s.
Before you start to use your new product please read this manual (especially the chapter No. 5.1 -
Operation of boiler by user, and Chapter 8 – Important notices) so that from the beginning you get
used to its proper handling. Please respect the following information, thereby ensuring a long
trouble-free operation of your boiler to both your and our satisfaction.
1.
Produced variants of boilers
1.1
Order
Following data must be specified in the order:
Order specification code
HEFAISTOS P1 X X
2.
Technical information
Boiler Hefaistos P1 is a pyrolytic sectional cast-iron low pressure boiler with a metal sheet feed hopper
designed for burning the lump wood.
The control of boiler Hefaistos P1 T (thermostatic option) is solved by means of thermostats (in operation,
flue gases and pump -see chapter 4.3.1.).
Note: The thermostatic variant is used 6 – 7-sectional models.
The control of boiler Hefaistos P1 E (electronic version) is solved by means of controller ST 81.
Note: The electronic version is only applied to 3 – 5-sectional models.
The ventilator is equipped with a probe for speed sensing.
Combustion of other fuels and materials such as plastics is not permissible.
2.1
The use of boiler
Three-section model of boiler Hefaistos P1 is suitable for heating the family houses. Larger sizes of the
boiler meet the requirements of shops, schools, recreational facilities, weekend houses etc.
The boiler is manufactured as the hot water boiler with forced heating water circulation and working
overpressure up to 400 kPa (4 bar). Before the dispatch the boiler is tested for leakage by applying the test
overpressure of 800 kPa (8 bar).
The boiler is designed for heating both in closed and open heating systems.
The boiler must be designed with one of these options of connection:
•
storage tanks
•
three-way valve
•
four-way valve
•
ladomat
2.2
Advantages of boiler
1.
High service life of cast-iron heat exchanger and all other parts due to the quality of the materials.
2.
Sophisticated manufacturing technology on automatic moulding lines with stable and proven quality of
manufacturing process (ISO 9001, ISO 14001).
3.
Combustion efficiency 83 – 89%.
4.
Simple operation and maintenance.
5.
Gradation of performance according to number of sections.
6.
The version Hefaistos P1 E allows hot water preparation with the possibility to select the strategy of
boiler control.
Boiler size:
3: 3 sect. model
4: 4 sect. model
5: 5 sect. model
6: 6 sect. model
7: 7 sect. model
Boiler control:
T: thermostatic
E: electronic