13
5.2.1.2
Placement of the shaped pieces set, tertiary air nozzle and inclined grate for the boiler with a size of 6
to 9 sections (Fig. No. 16)
1.
Place to the bottom part of the combustion chamber the bottom left shaped piece (1), bottom right shaped piece (2) and up to it - middle
rear shaped piece (3) and upper rear shaped piece. (5)
Fig. №. 14
2.
Apply heat-resistant glue (glue-fibers of 3-4 mm) to the bottom part of the nozzle of the supply-line of tertiary air (7),
and place the nozzle straightly into the circular hole of the shaped piece (1)(2).
Fig. №. 15
3.
Close the combustion chamber by inserting the middle front shaped piece (4) and upper front shaped piece (6).
4.
Insert carefully the inclined grate (8) into the combustion space, and prop its upper part on the front section.
Fig. №. 16 Placement of the shaped pieces into the combustion chamber of the HERCULES E68 boiler
1. Bottom left shaped piece
2. Bottom right shaped piece
3. Middle rear shaped piece
4. Middle front shaped piece
5. Upper rear shaped piece
6. Upper front shaped piece
7. Tertiary air nozzle