Dear customer,
We thank you that you have bought a
HERCULES E68
boiler, thus having shown your confidence in VIADRUS brand.
To get you accustom from the very beginning to correct handling with your new boiler, please firstly read this manual for its using, especially
Chapter No. 7.
– Boiler servicing by an user, Chapter No. 8 – Maintenance, and Chapter No. 9 – Important warning. Please observe the below
mentioned information, in order to ensure a long-term trouble-free operation to your and our satisfaction.
HERCULES E68
boiler is a cast-iron sectional gasifying boiler designed for the combustion of wood.
Combustion of other substances (for example, plastics) is not allowable.
1
Boiler usage and advantages
The
HERCULES E68
boiler meets the requirements for heating of one-family houses, shops, etc.
The boiler is manufactured as a warm-water boiler with forced circulation of heating water and work overpressure up to 400 kPa (4 bar). Before
dispatching, the unit is tested with the testing overpressure of 800 kPa (8 bar). The control of the
HERCULES E68
boiler is solved with help of
automatic regulation.
Advantages of the boiler:
1. Ecological operation
2. High effectiveness of the boiler
3. Low fuel consumption
4. High service life of the cast-iron heat-exchanger and all other parts thanks to the quality of the used materials.
5. Long-term proven structure.
6. Sophisticated production technology on the automatic forming lines with permanent and proven quality of the production process (ISO 9001,
ISO 14 001).
7. Simple manipulation and maintenance.
8. Possibility of hot water heating
9. Possibility of the control of one heating circuit
10. Cooperation with storage tank
2
Technical parameters of the boiler HERCULES E68
Tab. №. 1
Boiler's sizes and technical parameters
Boiler size- number of sections
5
6
7
8
9
Combustion chamber volume
dm
3
32
32
45
59
73
Water content
l
40.5
46.5
52.5
58.5
64.5
Weight
kg
348
413
458
503
549
Combustion chamber depth
mm
255
255
365
475
585
Chimney throat diameter Ø D
mm
160
160
160
160
160
Boiler sizes: - height x width
mm
1160x683
1160x683
1160x683
1160x683
1160x683
- depth L
mm
1070
1180
1290
1400
1510
Feed port sizes
mm
310 x 236
310 x 236
310 x 236
310 x 236
310 x 236
Maximum operation water overpressure
kPa (bar)
400 (4)
400 (4)
400 (4)
400 (4)
400 (4)
Minimum operation water overpressure
kPa (bar)
50 (0.5)
50 (0.5)
50 (0.5)
50 (0.5)
50 (0.5)
Testing water overpressure
kPa (bar)
800 (8)
800 (8)
800 (8)
800 (8)
800 (8)
Hydraulic loss
mbar
see Fig. No. 1
see Fig. No. 1
see Fig. No. 1
see Fig. No. 1
see Fig. No. 1
Minimum input water temperature
°C
50
50
50
50
50
Recommended minimum output water
temperature
°C
70
70
70
70
70
Noise level
dB
< 65
< 65
< 65
< 65
< 65
Boiler connections: - heating water
2“
2“
2“
2“
2“
- return water
2“
2“
2“
2“
2“
Cooling
water
temperature
for
the
redundant heat exhaust device
°C
5
– 20
5
– 20
5
– 20
5
– 20
5
– 20
Cooling
water
overpressure
for
the
redundant heat exhaust device
kPa (bar)
200
–600 (2-6)
200
–600 (2-6)
200
–600 (2-6) 200–600 (2-6) 200–600 (2-6)
Electrical voltage
1/N/PE 230 V AC 50 Hz, TN-S
Electrical input at nominal power
W
11
15
13
21
34
Electrical input at standby state
W
4
Electric cover
IP 40
Tab. №. 2
Technical parameters of HERCULES E68, Values corresponds to the fuel used upon certification:
Hard wood - class A; fuel humidity: max. 16-18 %; calorific value: min.15
– 18 MJ. kg
-1
Boiler size- number of sections
5
6
7
8
9
Boiler class according to EN 303
– 5
-
5
5
5
5
5
Nominal power
kW
15
18
23
27
34
Fuel consumption
kg/h
3.7
4.3
5.3
6.9
8.5
Max. fuel weight in the feeding chamber
kg
13
13
18
22
25
Flue gases temperature at the nominal power
°C
140-180
140-180
140-180
140-180
140-180
Flue gases mass flow rate at the nominal power
kg/s
0.011
0.014
0.017
0.019
0.026
Chimney draught
mbar
0.18
0.16
0.18
0.20
0.20
Combustion time
h
min. 2
min. 2
min. 2
min. 2
min. 2
Efficiency
%
88.3
88.3
89.1
88.5
89.0
Energy efficiency class
A+
A+
A+
A+
A+
Energy efficiency index
114
114
114
113
114
Season energy efficiency
%
77
77
78
77
77