Troubleshooting
Troubleshooting
Phenomenon
Cause
Measure
It is not possible to
eliminate static electricity.
The appropriate input voltage is not
being supplied to the GP-1.
Check the output voltage and the polarity of the
AC adapter or the DC power supply.
Sparks are emitted when
the power is turned on.
The setting of the output voltage of
the GP-1 is not correct.
Adjust the output voltage of the GP-1 to be an
appropriate one. *
The output voltage is high due to
heavy load.
Adjust the output voltage. Otherwise, reduce the
load (reducing the number of bodies to be
connected to the GP-1, or replacing with the
optional short high-voltage cable.) *
Cannot measure voltage
on output monitoring
terminal.
Too small impedance of testers.
Input impedance should greater than 1Mohm.
Cannot fine tune high
voltage output.
Wrong finer tune volume.
There are three volumes for each output high
voltage ranges (4kV, 5kV, 7kV).
Malfunction of finer tune volume.
Contact your local dealer for repair service.
Cannot adjust ion
balance.
Capacitive coupling electrodes.
Capacitance coupling electrodes cannot adjust
ion balance.
The anomaly detection
circuit of the power
supply GP-1 is triggered
to stop output.
Bad ground.
Check conduction between the gun tip part
(stainless steel) and the ground wire.
The load is too great.
Decrease the load. (reducing the number of
bodies to be connected to the GP-1 or replacing
with the optional short high-voltage cable.) *
The electrode and insulation of
electrode body are extremely dirty.
Clean or replace the electrode, etc.
Failure of the electrodes or the
high voltage cable (short circuit,
etc.).
If the GP-1 stops detecting anomaly when the
high voltage cable is disconnected, replace the
electrode and the high voltage cable.
Breakdown of the GP-1.
If the GP-1 continues detecting anomaly even
after the high voltage cable is disconnected,
repair or replace the GP-1.
* Contact the dealer from which the product was purchased for options.
Note: Replacement of electrode is an option by our factory.
■
Storage
Caution
PROHIBITED
Do not store the product in the following locations. There is a risk of product
breakdown.
・
Where considerable vibration or shock is transmitted to the unit
・
Areas with heat, humidity or condensation exceeding the range shown in the
specifications
・
Areas where an abrupt temperature change occurs
・
Areas where there is a risk of ignition or explosion such as near flammable
solvent or dust powder
・
Areas with a lot of dust and smoke, or where water, oil, or chemicals may be
poured on the product
・
Areas where an intensive electric field or ferromagnetic field is generated