26
■
Installation
Setting output voltage range (cont.)
Warning
PROHIBITED
・
DO NOT use electrodes on incorrect voltage range.
・
DO NOT stop the dial of output voltage switcher in the middle of scale.
・
DO NOT turn on main switch without clear feeling of click when moving the dial
of output voltage switcher.
Caution
・
DO NOT turn on main switch without output voltage seal.
・
Output voltage seal should be replaced as soon as possible after output voltage
was changed.
・
Double check output voltage before connect new electrodes.
・
Do not touch parts except the output voltage switcher.
・
Do not remove or injure inner earth wire on upper cover.
・
Do not turn on main switch without upper cover.
Fine adjustment of output voltage
Output voltage can be adjusted by finer tuning volumes.
Voltage
range
Lower voltage
(
kV
)
Upper voltage
(
kV
)
4kV
3.5
4.2
5kV
4.2
5.2
7kV
6.0
7.2
①
Turn off main switch.
*Electrodes can be keep connecting.
②
Take care with inside earth code, slowly lift up
upper cover from the side of main switch. Do not
remove / insured inside earth wire.
③
There are three volumes for finer tuning for
each output voltage range. Please confirm which
is the dial for finer tuning of your output voltage
(right picture).
④
Connect voltage tester to output monitoring
terminal (refer p.24).
⑤
Confirm the probe of tester is connected to output monitoring terminal correctly.
⑥
Connect electrode(s) if it is not connected until this step (please refer p.28) then turn on the main
switch. Parts and internal circuit boards may be powered and charged by high voltage electricity after
turning on the main switch. Take care for preventing metal materials or tools from dropping / touching
on those parts. Volume shall be operated by isolated tolls (recommended tool:
VESSEL
№9000
+1.7×30).
⑦
Slightly rotate the dial of finer tuning volume while checking indicated value of voltage tester. The
finer tuning volume is precise parts. Do not rotate the volume with too much force. Also, there is
maximum value / position. Stop rotation if there is a feeling of stop while rotating the volume. The
volume is non-step type.
Finer tune volumes
4kV
5kV
7kV