Caution
Caution
Always use AC voltage testing mode.
Do not apply voltage to output monitor terminal. That may cause fatal damage to
inside circuits.
Measure output voltage after connecting electrodes. Output voltage will be
indicated slightly higher without electrodes.
REMEMBER
Do not short output monitoring terminal or connect to ground. That may cause
fatal damage to inside circuits.
Adjusting output voltage
Output voltage can be adjusted to fit to electrodes or installation / condition.
voltage settings after replacing electrodes. This proce
dure is not needed if your package is all-in-one type.
Setting output voltage range
①
Turn off main switch.
*Electrodes can be keep connecting.
②
Take care with inside earth code, slowly lift
up upper cover from the side of main switch. Do
not remove / insured inside earth wire.
③
Confirm specificated voltage of electrodes in
the table below, set output voltage switcher.
Voltage switcher is sensitive parts. Do not put
too much force. You may feel small click when
the dial places at correct position.
Recommended
Voltage
Dial
Position
Output voltage seal
4kV
1
5kV
2
(No electrode for this voltage at the time
of publishing of this document.)
7kV
3
④
Close the upper cover after selecting voltage range, double check the inside earth
upper cover as it was before.
⑤
Connect electrode(s) if it is not connected until this step (please refer p.28
and check output voltage using output monitoring terminals.
⑥
Output voltage seal shall be replaced after changing output voltage range.
the package of the new electrode.
⑦
Please refer p.26 if finer tuning needed.
25
■
Installation
o not apply voltage to output monitor terminal. That may cause fatal damage to
Measure output voltage after connecting electrodes. Output voltage will be
o not short output monitoring terminal or connect to ground. That may cause
utput voltage can be adjusted to fit to electrodes or installation / condition. Please confirm output
utput voltage seal
Color of output
voltage seal
Red
o electrode for this voltage at the time
of publishing of this document.)
Blue
the inside earth wire is fixed to
28), turn on the main switch
voltage seal shall be replaced after changing output voltage range. It should be included in
Output voltage switcher