Starting
Turn on main switch (POWER) to ON
●
sign then pilot lamp turns on blue and high voltage output will
〇
Pilot lamp turns on
〇
Alarm terminal will be in normal mode
□
High voltage output terminal outputs 1/1000 attenuated voltage of actual high voltage outputs.
〇
High voltage electricity will be supplied to electrodes and start generating ion.
Stopping
Turn off main switch (POWER) to OFF
○
sign then pilot lamp turns off and high voltage output will stop.
〇
Pilot lamp turns off
〇
Alarm terminal will be power off state
□
High voltage output terminal outputs to 0V.
〇
High voltage electricity to electrodes will be shunted down.
Anomaly detection
High voltage output and pilot lamp will automatically turn off when abnormally condition of high voltage cable,
electrodes and / or GP-1.
〇
Pilot lamp turns off
〇
Alarm terminal will be alarm state
□
High voltage output terminal outputs to 0V.
〇
High voltage electricity to electrodes will be shunted down.
*Turn off the main switch and remove the cause of the trouble.
Resetting / Recovering from anomaly state
Turn on the main switch after removing the cause of the trouble.
〇
GP-1 will back to normal mode
*Anomaly detection will activate again if there is still cause of the trouble.
Tweaking ion balance
DC voltage (offset) can be mixed with AC high voltage output using Ion balance adjuster
electrode.
①
The ion balance adjuster on same side of main switch.
②
The volume is signed as ION BALANCE ADJ.
③
To adjust ion balance please rotate the volume.
④
Adjust ion balance using CPM (charged plate monitor) in normal
mode.
All-in-one package
Ion balance, voltage range and finer voltage was pre-tuned in factory for all-
However, ion balance may be affected by distance from working material, condition of
or circumstance, therefore shall be checked and tuned at the actual place of the working.
Caution
REMEMBER
・
Install one electrode only if ion balance is very important
・
Ion balance adjuster works for all high voltage outputs
voltage output individually).
・
Some electrodes cannot adjust ion balance completely (lesser precision).
Please refer the instruction manual for electrodes.
29
■
Operation
high voltage output will start.
voltage of actual high voltage outputs.
electricity will be supplied to electrodes and start generating ion.
sign then pilot lamp turns off and high voltage output will stop.
condition of high voltage cable,
Ion balance adjuster to adjust ion balance of
-in-one package (HPG-1-S).
owever, ion balance may be affected by distance from working material, condition of compressed air
al place of the working.
ion balance is very important.
adjuster works for all high voltage outputs (cannot adjust high
ion balance completely (lesser precision).
Summary of Contents for StatClean GP-1
Page 5: ...5 外観寸法 ...
Page 6: ...6 回路ブロック図 ...