background image

Vertical SUMMIT IP 

Hardware Description and Installation Manual

 

Issue 1.2 

 

86 

11. The IP Information page establishes the IP address scheme. DHCP can be enabled or 

static addressing can be configured. When the system is behind a firewall, the Firewall 
address must be entered allowing proper operation with remote users, devise and SIP 
trunks. A DNS (Directory Name Server) for Domain Name resolution should also be 
entered on this page. Note that changing any IP address in the system requires a system 
reset; the reset does not initialize data. 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for SUMMIT IP

Page 1: ...Hardware Description Installation Manual ...

Page 2: ...ice The Vertical SUMMIT IP complies with rules regarding radiation and radio frequency emission as defined by local regulatory agencies In accordance with these agencies you may be required to provide information such as the following to the end user FCC CSA Interference Statement This equipment has been tested and found to comply with the limits of a Class A digital device pursuant to Part 15 of ...

Page 3: ...on of government regulations arising from failure to comply with these guidelines The device is certified to the requirements of RSS 210 for 2 4GHz spread spectrum devices WARNING This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures WARNING This equipment generates and uses R F energy and if n...

Page 4: ... than direct connections to the branch circuit e g use of power strips Replaceable batteries CAUTION Risk of Explosion if Battery is replaced by an Incorrect Type Dispose of Used Batteries According to the Instructions Leakage currents due to ringing voltage Earthing installation marking HIGH LEAKAGE CURRENT Connect permanent earthing conductor before connecting telephone lines Leakage currents du...

Page 5: ...e à celle de la pièce De ce fait vous devez envisager l installation de l équipement dans un environnement compatible avec la température ambiante maximale Tam indiquée par le fabricant B Débit d air réduit L installation de l équipement dans un bâti doit être effectuée de manière à ne pas compromettre le débit d air requis pour un fonctionnement en toute sécurité de l équipement C Charge mécaniqu...

Page 6: ...lorsque le cordon d alimentation est débranché La mise à la terre du conducteur de mise à la terre supplémentaire de l équipement doit être conforme aux règles appropriées pour les connecteurs terminaux de la section K de l article 250 du Code national de l électricité ANSI NFPA 70 et de l article 10 de la section 1 du Code canadien de l électricité section 1 C22 Le raccordement du conducteur de m...

Page 7: ... time without notice The information furnished by Vertical Communications in this material is believed to be accurate and reliable but is not warranted to be true in all cases If you are not the intended recipient you should destroy or retrieve this material to Vertical Communications All other brand and product names are trademarks or registered trademarks of their respective companies Issue Date...

Page 8: ...11 2 5 4 Wireless Terminal specification GDC 450H 480H 500H 11 3 INSTALLATION OVERVIEW 12 3 1 Pre Installation Guidelines 12 3 1 1 Safety Installation Instructions 12 3 1 2 Installation precautions 12 3 1 3 Wiring Precautions 13 3 1 4 Checking Power cord 13 3 2 Installation Overview 14 3 3 Preparation 14 4 BOARD INSTALLATION AND DESCRIPTION 17 4 1 General information 17 4 2 Removing and Replacing ...

Page 9: ...3 4 7 4 VS 5030 00 Modem Function Unit 44 5 MOUNTING THE KSU AND EKSU 45 5 1 KSU Exterior and Dimension 45 5 2 Desk Mount 46 5 3 Wall Mount 47 5 4 Rack Mount 48 6 KSU WIRING 50 6 1 Connecting the SUMMIT IP and Expansion KSUs 50 6 2 Grounding the KSUs 51 6 3 External Backup Battery Installation 53 6 4 Line and Station Modular Jack Wiring 55 6 4 1 CO Line Modular Jack Wiring 55 6 4 2 PRI Line Modula...

Page 10: ...7 3 4 DSS BLF Console Installation Wiring 73 7 4 Terminal Wall Mount 77 7 4 1 LDP 7000 9000 9200 series Wall Mount 77 7 4 2 LIP 8000 8000E Wall Mount 77 7 4 3 LIP 9000 Wall Mount 78 8 STARTING THE VERTICAL SUMMIT IP 79 8 1 Vertical SUMMIT IP System Initial Power up 79 8 2 Verify the Nation Code 80 8 2 1 Using the DKT 80 8 3 Installation Wizard 81 9 MAINTENANCE TROUBLESHOOTING 87 9 1 General Mainte...

Page 11: ... not sure of the type of power supply to your location consult your dealer or local power company Do not allow anything to rest on the power cord Do not locate this product where the cord could be abused by people walking on it Do not overload wall outlets and extension cords as this can result in the risk of fire or electric shock Never push objects of any kind into this product through KSU slots...

Page 12: ...and return this system to your dealer To prevent the risk of fire electric shock or failure of the system do not expose this product to rain or any type of moisture To protect the internal components from static electricity discharge body static before touching connectors and or components by touching ground or wearing a ground strap To reduce the risk of fire use only No 26 AWG or larger e g 24 A...

Page 13: ...to install the Vertical SUMMIT IP System Section 4 Board Installation Description Provides a description and instructions for installing components of the Vertical SUMMIT IP Section 5 Mounting the KSU and EKSU Provides instructions for mounting the KSU and EKSU Section 6 KSU and EKSU Wiring Provides instructions on wiring the KSU and EKSU including Modular jacks for Lines stations LAN ports and Mi...

Page 14: ... and E mail notification In addition the SUMMIT IP is compatible with Ericsson LG Enterprise optional advanced communication applications supporting TAPI desktop softphones Unified Communication Call Center operation and more Details on these advanced applications are available in the respective product manuals available from Ericsson LG Enterprise 2 2 General Cabinet Description The SUMMIT IP sys...

Page 15: ...Vertical SUMMIT IP Hardware Description and Installation Manual Issue 1 2 2 Figure 2 2 1 SUMMIT IP KSU Appearance Figure 2 2 2 EKSU Appearance ...

Page 16: ...anual Issue 1 2 3 2 3 System Connection Diagram The following figure represents the interconnections available with the Vertical SUMMIT IP including external network terminals miscellaneous and admin interfaces Figure 2 3 1 System Connection Diagram SUMMIT IP ...

Page 17: ...d 4 SLT Interfaces Voice Mail 4 channels 1 hour default 8 channel 32 hours Max VoIP 2 channels default 16 channels Max KSUID MBUID 8 DKT and 4 SLT Interfaces Voice Mail 4 channels 1 hour default 8 channels 32 hours Max VoIP 2 channels default 16 channels Max EKSU EMBU 4 CO and 8 Hybrid PSU Power Supply Unit pre installed in each cabinet Interface Boards VS 5032 24 2 CO Line and 4 Hybrid Interface ...

Page 18: ... KSUID EKSU Interface Boards VS 5032 24 Y Y Y VS 5032 48 Y Y Y VS 5033 416 Y Y Y VS 5035 00 N Y N VS 5032 99 Y Y N Function Boards VS 5080 00 Y Y N VOIB48 Y Y N VS 5080 01 Y Y N MEMU2 Y Y N VS 5030 00 Y Y N NOTE Each KSU permits installation of two 2 Interface boards However only one 1 CS416 SLB16 or WTIB4 Interface board may be installed in a KSU ...

Page 19: ...m External Paging Port 0 dBm 600 ohm Ring Detect Sensitivity 30 Vrms 16 55 Hz DTMF Dialing Frequency Deviation Less than 1 8 Signal Rise Time 5 ms Tone Duration on time Min 50 ms Normal 100 ms Inter digit Time Min 30 ms Normal 100 ms Pulse Dialing Pulse Rate 10 PPS Break Make Ratio 60 40 or 66 33 Operating Environment Temperature 0 o C 40 o C Humidity 0 80 non condensing Dimension KSU 307 mm W x 2...

Page 20: ...dants 4 LAN port 2 1 each SUMMIT IP KSU and VVMU Modem Channel 1 MODU Serial Port RS 232C 1 USB 2 0 Host port 1 Alarm Doorbell input 2 1 per KSU External Control Relays 2 1 per KSU Music Source Inputs 1 Internal select one of 13 melodies 1 External source input 5 SLT ports 3 VSF announcements Power Fail Circuit Max 6 1 per SUMMIT IP KSU EKSU CH204 CH408 CS416 VSF Device 1 Built in AA VM w MEMU w M...

Page 21: ...0 23 digits programmable DSS Consoles per Station 3 Serial DSS System 100 Serial DSS Station LIP 8000 4 Serial DSS Station LIP 9000 1 SMDR buffer 5000 CO Line Groups 20 Station Station Groups 40 Station Station Group Members 70 Pickup Group 50 Pickup Group Member 140 Conference Groups System 40 Conference Groups Station 20 per station Executive Secretary pairs 36 Authorization Codes 500 Station 14...

Page 22: ...nes EKSU CO Line 12 2 CH408 CD408 or 1 CH408 CD408 1 CS416 KSUAD EKSU CO Line 24 SIP Trunk 56 channels Stations KSUAD DKT 24 4 SLT 2 CH408 CD408 SLT 28 8 DKT 1 CH408 1 CS416 LIP SIP 96 VOIU 8 VOIB48 Shared w SIP Trunks 56 simultaneous calls DECT 48 24 simultaneous calls EKSU DKT 24 2 CH408 CD408 SLT 32 1 CH408 1CS416 KSUAD EKSU DKT 48 4SLT SLT 60 8 DKT LIP SIP 96 SIP Phones require per seat licens...

Page 23: ...KSUID CO Line 12 2 CH408 CD408 or 1 CH408 CD408 1 CS416 KSUID EKSU CO Line 20 PRI T1 Line 23 1 24 channels SIP Trunk 56 channels Stations KSUID DKT 24 4 SLTs 2 CH408 CD408 SLT 28 8 DKT 1 CH408 1 CS416 LIP SIP 96 VOIU 8 VOIB48 Shared w SIP Trunks 56 simultaneous calls DECT 48 WTIB4 24 simultaneous calls EKSU DKT 24 2 CH408 SLT 32 1 CH408 1CS416 KSUID EKSU DKT 48 4 SLT SLT 60 8 DKT LIP SIP 96 SIP Ph...

Page 24: ...ssion Max Power 100mW Access Method Duplex TDMA TDD Frequency Band 1 920 1 930MHz Channel Spacing 1 728MHz Modulation GFSK Data rate 1 152Mbps Base Station distance to WTIB4 600m twisted 2 pair cable maximum 2 5 4 Wireless Terminal specification GDC 450H 480H 500H Table 2 5 4 1 DECT Handset Specifications Item Specification Transmission Power 250mW maximum Modulation Method GFSK Frequency Band 1 9...

Page 25: ...has been disconnected at the network interface Use caution when installing or modifying telephone lines Anti static precautions should be taken during installation of optional boards in a KSU 3 1 2 Installation precautions The Vertical SUMMIT IP KSUs are designed for desktop mounting wall mounting or a free standing rack mounting In no case should one cabinet be mounted on top of the other when de...

Page 26: ...the extension line and then re connect or turn the System power OFF and then ON again Use twisted pair cable for connecting CO lines 3 1 4 Checking Power cord Checking the power cord at least once a year to prevent fire hazard or electric shock Be sure to disconnect the power cord from the wall outlet and System s inlet for the following symptoms 1 Burn marks on the plug 2 The prongs on the plug a...

Page 27: ...ocal Ericsson LG Enterprise representative 3 3 Preparation In preparation for the installation locate an appropriate site for the KSU installation considering the precautions mentioned in earlier sections wiring access to power etc Also if installing DECT locate the best estimated position for the Base Stations The permanent location of the Base Station will be determined using the GDC 600TBE CSR ...

Page 28: ...Vertical SUMMIT IP Hardware Description and Installation Manual Issue 1 2 15 Figure 3 1 SUMMIT IP KSU Carton Contents ...

Page 29: ...Vertical SUMMIT IP Hardware Description and Installation Manual Issue 1 2 16 Figure 3 2 EKSU Carton Contents ...

Page 30: ...various components and step by step instructions to mount the option boards 4 2 Removing and Replacing the KSU Cord Cover Prior to installing option boards in the KSU or EKSU it is necessary to remove the KSU and Cord covers To remove the cord KSU cover and expose the MBU 1 Locate and remove the Cord cover hold down screw as shown in 1 in the below figure 2 Press down slightly on the top of the Co...

Page 31: ... covers reverse the removal procedure as below 1 Insert the tabs of the KSU cover into the KSU slots 2 Press the KSU cover down on to the KSU 3 Insert the screws and tighten screws with screwdriver to fix the front cover 4 Install the Cord cover 5 Insert and tighten the cover hold down screw ...

Page 32: ...tailed in section 4 2 2 For an Interface board remove the modular jack cover plate as shown in 1 3 If the board is provided with standoffs remove two screws holding the MBU in the locations indicated in the figure 4 Insert 2 standoffs through the MBU and into the cabinet Tighten the standoffs with Wrench as shown in 2 5 Holding the board as shown in 3 insert the board carefully in the direction of...

Page 33: ...ll Progress Tone CPT detection The SLT line interface of the Hybrid ports supports FSK ITU T V 23 or Bell 202 or DTMF ITU T Q 23 Caller ID and the Message Wait Indication MWI DTMF detection sinusoidal ringing generator 48V DC feeding voltage current limiting and GR 909 Line Testing function A VoIP channel is required to support each SIP Trunk line LIP or SIP Phone and remote users and devices The ...

Page 34: ... 2 channels maximum 4 channels with license Master Clock Generation PLL circuit 1 PFT circuit CO1 connects to the last SLT port STA12 1 RS 232C Interface circuit 1 LAN Interface USB interface circuit PCM Voice Processing circuit ACT2 ASIC voice switching including DSP PCM Tone Generation and PCM Gain Control Tone DTMF CPT FAX detection and CID Signal FSK DTMF RUS CID detection NOTE Should AC Power...

Page 35: ...h CO lines 3 4 MJ2 8 DKT and 4 SLT ports 12 ports MJ3 LAN USB Port 1 LAN 1 USB MJ4 Relay Alarm Page External MOH Connection 1 Port SW1 2 pole Database protect switch SW2 Push button System reset switch Switch setting Table 4 4 1 2 MBUAD SW1 2 pole Dip switch Pole Function Switch State Remarks ON OFF 1 Database protection Protect database no admin allowed Unprotect Default OFF 2 Initialization for ...

Page 36: ...g voltage current limiting and GR 909 Line Testing function A VoIP channel is required to support each SIP Trunk line LIP or SIP Phone and remote users and devices The two 2 basic VoIP channels on the MBU can be increased to eight 8 with an unlock code As shown in the figure the MBU has connectors for the various option boards including connector CN1 which is used to connect optional Interface boa...

Page 37: ...ilt in VM channel default 2 channels maximum 4 channels with license Master Clock Generation PLL circuit 1 RS 232C Interface circuit 1 LAN Interface USB interface circuit PCM Voice Processing circuit ACT2 ASIC voice switching including DSP PCM Tone Generation and PCM Gain Control Tone DTMF CPT FAX detection and CID Signal FSK DTMF RUS CID detection NOTE Should AC Power fail the last SLT port on MB...

Page 38: ...nd 4 SLT ports 12 ports MJ3 LAN USB Port 1 LAN 1 USB MJ4 Relay Alarm Page External MOH Connection 1 Port SW1 2 pole Database protect switch SW2 Push button System reset switch Switch setting Table 4 4 2 2 MBUID SW1 2 pole Dip switch Pole Function Switch State Remarks ON OFF 1 Database protection Protect database no admin allowed Unprotect Default OFF 2 Initialization for Database Initialize Databa...

Page 39: ...ion MWI DTMF detection sinusoidal ringing generator 48V DC feeding voltage current limiting and GR 909 Line Testing function As shown in the figure the EMBU has connector CN1 for the various Interface boards and connectors and CN8 and CN9 for installation of the Call metering CO Line daughter board for the built in CO lines A maximum of two 2 Interface boards can be installed with the first board ...

Page 40: ...s Jacks and Switches The following chart lists the various connectors for option boards RJ modular jacks for connecting CO Lines Stations and miscellaneous functions and switches on the Main Board Table 4 5 1 EKSU with EMBU Connector Modular Jack and Switch Function Connector Functions Remark CN1 CO and Extension board installation 70 pins CN5 CN6 Connection KSU to EKSU with Expansion cable 19 pin...

Page 41: ... wire CH408 4 CO Line and 8 Hybrid ports RJ45 RJ11 2 wire CD408 4 CO Line and 8 DKT ports RJ45 RJ11 2 wire CS416 4 CO Line 16 SLT ports RJ45 RJ11 2 wire PRIU 1 PRI 24 T1 channels or 23B 1D PRI channels RJ45 4 wire HYB8 8 Hybrid ports RJ11 2 wire SLB16 16 SLT ports RJ11 2 wire DTIB8 8 DKT ports RJ 11 2 wire WTIB4 4 Base Station ports RJ11 4 wire The CO line ports of the Interface boards support loo...

Page 42: ... 4 3 Figure 4 6 1 1 CH204 Connector and Modular jack The following chart indicates the connectors and modular jacks equipped on the CH204 Table 4 6 1 1 Connector and Modular Jack Function Connector Functions Remark CN1 Pass through to second Interface board 70 pins CN2 Connection to CN1 connector of MBU 70 pins CN3 CPLD JTAG for development 10 pins CN790 CN791 MG CMU4 Installation Not used MJ1 1 2...

Page 43: ...Figure 4 6 2 1 CH408 Connector and Modular jack The following chart indicates the connectors and modular jacks equipped on the CH408 Table 4 6 2 1 Connector and Modular Jack Function Connector Functions Remark CN1 Pass through to second Interface board 70 pins CN2 Connection to CN1 connector of MBU 70 pins CN3 CPLD JTAG for development 10 pins CN790 CN791 MG CMU4 Installation Not used MJ1 1 2 CO l...

Page 44: ...the board in the KSU refer to Section 4 3 Figure 4 6 3 1 CD408 Connector and Modular jack The following chart indicates the connectors and modular jacks equipped on the CD408 Table 4 6 3 1 Connector and Modular Jack Function Connector Functions Remark CN1 Pass through to second Interface board 70 pins CN2 Connection to CN1 connector of MBU 70 pins CN3 CPLD JTAG for development 10 pins CN790 CN791 ...

Page 45: ...at must be installed prior to mounting the board To install the board in the KSU refer to Section 4 3 Note the CS416 does not include a pass through connector and thus should be installed as the top Interface board on connector CN1 Figure 4 6 4 1 CS416 Connector and Modular jack The following chart indicates the connectors and modular jacks equipped on the CS416 Table 4 6 4 1 Connector and Modular...

Page 46: ...IA 464 A and TR 41458 24 channel interface supporting DID TIE Line and Loop or Ground Start are implemented The DID and TIE Line operation support Immediate Delayed and Wink start signaling protocols The interface can be assigned for AMI or BZ8S line coding and either D4 or Extended Super Frame ESF framing In PRI operation the ISDN standard 23 Bearer and one 1 Data channel interface is supported i...

Page 47: ...0 Pins MJ1 PRI T1 line RJ45 Switch setting Table 4 6 5 2 PRIU PRI T1 Function SW1 Pole Function Operating Mode Remarks ON OFF 1 T1 or PRI mode T1 PRI mode Default OFF 2 Reserved LED Indications Table 4 6 5 3 PRIU LED Indications LED Color Description LD1 Blue ON FPGA programmed OFF FPGA not programmed LD2 Blue Flash 500ms normal LD3 Blue ON PRI channel in use OFF All PRI channels idle LD4 Red ON L...

Page 48: ...with two Standoffs that must be installed prior to mounting the board To install the board in the KSU refer to Section 4 3 Figure 4 6 6 1 HYB8 Connector and Modular jack Table 4 6 6 1 Connector and Modular Jack Function Connector Functions Remark CN1 Connection to second option board 70 pins CN2 Connection to MBU CN1 connector 70 pins CN3 CPLD JTAG for development 10 pins MJ2 8 DKT or SLT line RJ1...

Page 49: ...ds for the DTIB8 The board is provided with two Standoffs that must be installed prior to mounting the board To install the board in the KSU refer to Section 4 3 Figure 4 6 7 1 DTIB8 Connector and Modular jack Table 4 6 7 1 Connector and Modular Jack Function Connector Functions Remark CN1 Connection to second option board 70 pins CN2 Connection to MBU CN1 connector 70 pins CN3 CPLD JTAG for devel...

Page 50: ...offs that must be installed prior to mounting the board To install the board in the KSU refer to Section 4 3 Note the SLB16 does not include a pass through connector and thus should be installed as the top Interface board Figure 4 6 8 1 SLB16 Connector and Modular jack Table 4 6 8 1 Connector and Modular Jack Function Connector Functions Remark CN2 Connection to CN1 of Interface board 70 pins CN3 ...

Page 51: ...recommend installing the WTIB4 as the second Interface board on the KSU CN1 connector The board is provided with two Standoffs that must be installed prior to mounting the board To install the board in the KSU refer to Section 4 3 Figure 4 6 9 1 WTIB4 With the WTIB4 a DECT network of four 4 cells Base Stations each handling 6 simultaneous calls from up to 48 subscribed stations can be configured T...

Page 52: ...tch Pole Functions ON OFF Default 1 Operation TBR6 mode Normal service mode OFF 2 Echo canceller Control Echo canceller on Echo canceller off ON 3 Reserved Reserved Reserved ON 4 Base reset mode All base reset One base reset OFF LED Indications Table 4 6 9 4 LED Indications LED Description LD1 HDLC Interrupt LD2 400ms flash LD3 Reserved LD4 ON Echo canceller enable OFF Echo canceller disable ...

Page 53: ...ice Mail channels and expands the memory for Voice Mail storage In addition the LAN port equipped on the VVMU provides the interface to the VVMU VoIP channels and for software applications that can be installed in the SUMMIT IP The VVMU is installed on the SUMMIT IP KSU MBU connectors CN3 as described in section 4 4 Table 4 7 1 1 VVMU VoIP and Voice Mail Capacity Chart Function Basic Unlock code l...

Page 54: ...D2 Speed ON 100Mbps OFF 10Mbps 4 7 1 VOIB48 VoIP Unit Description The VOIB48 refer to Figure 4 7 2 1 below expands the number of VoIP channels available in the system The VOIB48 is installed on the SUMMIT IP KSU MBU connectors CN3 as described in section 4 4 VVMU can t be installed when using VOIB48 As shown in the VOIB48 capacity chart below the basic SUMMIT IP is equipped with eight 8 VoIP chann...

Page 55: ... Modular Jack Function Connector Functions Remark CN1 Connection to CN3 of the MBU 32 Pins CN3 CPLD JTAG for development 10 Pins CN2 CPU JTAG for development 20 Pins CN4 Maintenance Serial port 4 Pins Switch setting Table 4 7 2 3 VOIB48 Push Button Reset SW2 Switch Functions SW2 Reset push button LED Indications Table 4 7 2 4 VOIB48 LED Indication LED Color Description LD1 Blue Flash 300ms ON and ...

Page 56: ...single connector for mounting on CN15 of the SUMMIT IP KSU MBU The MEMU has no other connectors LEDs or switches Figure 4 7 3 1 MEMU 4 7 3 MEMU2 Memory Expansion Module Unit2 Description MEMU2 is equipped with Nand Flash memory used to expand the storage capacity of the SUMMIT IP Voice Mail by 60 hours As with the basic and VVMU storage the MEMU2 storage is non volatile and any messages are stored...

Page 57: ... shown in Figure 4 7 5 1 below provides an analog modem interface supporting Bell ITU T V 34 V 32BIS and V 90 protocols at baud rates of 300bps up to 33Kbps with automatic rate negotiation The MODU has one connector for installation on the CN4 connector on the KSU MBU There are no switches or LEDs located on the MODU Figure 4 7 5 1 VS 5030 00 ...

Page 58: ...nted this is general not recommended and Wall and Rack mount provide added safety and optimal operation environment NOTE While access to the interior of the KSU may be required during the initial power up we recommend that the KSU cover be installed during mounting or moving the KSU 5 1 KSU Exterior and Dimension The following Figure 5 1 1 provides the external dimensions of the KSU which are the ...

Page 59: ...le top In this case assure the EKSU and KSU are located side by side with a minimum of 5 cm separation NOTE Particularly when multiple optional Interface boards are installed the KSUs should be wall or rack mounted It is important that in no case should the KSU and EKSU be stacked one on top of the other as this will cause overheating Figure 5 2 1 Desktop Mount ...

Page 60: ...all 3 anchor plugs in the wall using the mounting template included for accurate placement 2 Insert the 3 screws into the anchor plug and tighten leaving about 1 8 inch of the screw shaft exposed 3 Hook the KSU onto the screws making sure that the System slides down securely 4 Repeat Step 1 through 3 for the EKSU Before installing the mounting template for EKSU assure the Expansion cable is a suff...

Page 61: ...t with the two locating slots on the bottom of the KSU and attach it to the KSU by moving the bracket in the direction of arrows 2 Assure the bracket is fully engaging then insert and tighten the two 2 screws to secure the bracket to the KSU 3 Affix the bracket with the KSU to the rack posts with the four 4 screws provided 4 Repeat Step 1 through Step 3 for the EKSU Before installing the mounting ...

Page 62: ...Vertical SUMMIT IP Hardware Description and Installation Manual Issue 1 2 49 Figure 5 4 1 Installing Rack Bracket and Rack Mount KSU EKSU ...

Page 63: ...olored cables terminated at each end in a connector The grey cable must be connected to the SUMMIT IP KSU L and EKSU L ports and black to the SUMMIT IP KSU R and EKSU R ports To connect perform the following steps 1 Connect the grey cable to both the SUMMIT IP KSU and EKSU L ports 2 Connect black cable to both the SUMMIT IP KSU and EKSU R ports 3 To fix the Expansion cable connector securely tight...

Page 64: ...2 1 Grounding to the earth CAUTION This equipment should be connected to a socket outlet with a protective ground connection The Earth Ground wire shall have green and yellow insulation and the cross sectional area of the conductor must equal to or greater than UL 1015 AWG 18 1 0mm Be sure to comply with applicable local regulations HIGH LEAKAGE CURRENT Connect permanent earthing conductor before ...

Page 65: ...cle 10 of Part 1 of the Canadian Electrical Code Part 1 C22 1 Termination of the supplementary earthing conductor is permitted to be made to building steel to a metal electrical raceway system or to any earthed item that is permanently and reliably connected to the electrical service equipment earthed Bare covered or insulated earthing conductors are acceptable A covered or insulated conductor mus...

Page 66: ...n To wire the Battery Back up 1 Using the Battery Back up cable provided connect the Red wire to the positive terminal of one of the batteries 2 Connect the Blue wire of the connector to the negative terminal of the second battery 3 Connect the non terminated negative and positive battery terminal s together with a fuse 10 A 250 Volts This series connection will provide the 24 VDC required by the ...

Page 67: ...TION It is recommended to use an external backup battery fuse 10A 250V between the battery and the System Recommended battery capacity is 24V 20AH MF the Vertical SUMMIT IP System should be able to operate more than 3 hours with batteries that are in good condition Carefully check the battery polarity with cable colors Red and Blue when connecting the battery to the System Do not short out the ext...

Page 68: ...e a minimum of 2 pair wiring and the cabling for the RJ45 should terminate all 4 pairs NOTE In many cases two interface circuits are terminated to a single modular jack Thus carefully wire the jacks with the pin assignments shown otherwise the interface circuits will not operate properly 6 4 1 CO Line Modular Jack Wiring CO Line modular jacks are terminated with two 2 CO Lines to an RJ45 jack as s...

Page 69: ...ng Connector Pin out Pin Number Signal Name Function RJ45 1 RX T TX T TE NT 2 RX R TX R TE NT 4 TX T RX T TE NT 5 TX R RX R TE NT 3 N A 6 N A 7 8 N A 6 4 3 Digital Station Modular Jack Wiring Digital Station modular jacks are terminated with one Digital station circuit to an RJ11 jack as shown in the chart below To wire the Digital Station modular jack 1 Wire each Digital Station modular jack to t...

Page 70: ... Connector Pin out Pin Number Signal Name RJ11 1 N A 2 SLT T 3 4 DKT T DKT R 5 SLT R 6 N A 6 4 5 DKT SLT Station Modular Jack Wiring The last four 4 built in Station ports of the KSUAD and KSUID provide both a Digital and SLT port These Station modular jacks are terminated with one Digital and one SLT circuit to an RJ11 jack as shown in the chart below Both the DKT and SLT interface ports can be w...

Page 71: ...e After completing installation and initial power up of the SUMMIT IP system the DECT Base Stations can be located and installed as directed in the DECT Installation manual GDC 600TBE CRS tool user manual After installing the Base Stations the DECT handsets can be subscribed to the Base Stations and registered to the system To wire the WTIB4 modular jacks 1 Assure power to the KSU is OFF Failure t...

Page 72: ...tors Table 6 4 7 1 WTIB GDC 600BE Modular Jack Wiring Model Label Pin out Pin Number Pin Assignment Function WTIB4 WTI1 to WTI4 1 6 Unused reserved 2 RX GND Receive Data 3 TX 30V Transmit Data 4 TX 30v Transmit Data 5 RX GND Receive Data GDC 600BE MJ1 1 6 Unused reserved 2 Base TX GND Transmit Data 3 Base RX 30V Receive Data 4 Base RX 30v Receive Data 5 Base TX GND Transmit Data WTIB4 Automatic Li...

Page 73: ...he Command Line Interface follow the procedures outlined in the GDC 600BE Manual available from the local Ericsson LG Enterprise representative The results will appear in a format as follows The display will indicate OK NOT OK or Base eject Base not connected Welcome to Ericsson LG Enterprise WTIB4 Liu Test Program Ver 0 a E1 Line Test Start 01minutes During Test 00 59 E1 Line Test End Base eject ...

Page 74: ...1 MBU and VVMU LAN Modular Jack Wiring Connector Pin out Pin Numbers Signal Name Function RJ45 4 5 7 8 Reserved 1 TX Transmit Data 2 TX Transmit Data 3 RX Receive Data 6 RX Receive Data NOTE This equipment is indoor use and all the communication wirings are limited to inside of the building 6 6 USB port The SUMMIT IP KSU MBU incorporates a standard USB port The port is wired as shown in the chart ...

Page 75: ...e MOH connector External Paging Port wiring The Page connector allows paging audio to be sent to External Paging equipment The system will deliver audio as a 0 dBm signal into a 600 ohm load Relay Contact Output The Miscellaneous connector includes connection to an External Control Contact The External Control Contact activates as a Loud Bell a Door Open controller or control for External paging e...

Page 76: ...T Relay Contact Tip 2 RELAY_R Relay Contact Ring 3 ALARM_T Alarm Detection Tip 4 ALARM_R Alarm Detection Ring 5 EXTPAGE_T External Page Tip 6 EXTPAGE_R External Page Ring 7 EXTMOH_T External MOH Tip 8 EXTMOH_R External MOH Ring Table 6 7 2 EKSU Miscellaneous Connector MJ4 Wiring Connector Pin out Pin Number Signal Name Function RJ45 1 RELAY_T Relay Contact Tip 2 RELAY_R Relay Contact Ring 3 ALARM_...

Page 77: ...f the KSU and is terminated as in Table 6 8 1 Table 6 8 1 RS232 Port Wiring Connector Pin out Pin Number Signal Name Function RJ 232C 1 Not used 2 TD Transmitted Data 3 RD Received Data 4 DSR Data Set Ready 5 SG Signal Ground 6 DTR Data Terminal Ready 7 CTS Clear to Send 8 RTS Request to Send 9 Not used NOTE The RS 232C port on the MPB does not support hardware flow control Figure 6 8 1 RS 232 DB ...

Page 78: ...d and tie wrapped to the KSU s and to the wall or rack 6 9 1 Dressing the Wall Mount Wiring To dress wiring for a Wall mount installation 1 Ensure that all boards are installed and wiring is completed 2 Attach the Cord cover to the system 3 Using the supplied cable ties tie all wiring to the slot at the bottom right side of the KSUs as shown in Figure 6 9 1 1 Figure 6 9 1 1 Dressing the Wall Mount...

Page 79: ...pleted 2 Attach the Cord cover to the system 3 Using the supplied cable ties tie all wiring to the slot at the bottom right side of the KSUs as shown in Figure 6 9 2 1 4 Using additional cable ties not provided tie the bundled cables including Power cord and the Expansion cable using holes in the 19 Rack 5 Arrange the cable down the rack back to the wiring termination point Figure 6 9 2 1 Rack Mou...

Page 80: ...Display LDP 7048DSS 48 Button DSS DLS Console LDP DPB Door Phone Box LDP 9008D 8 Flexible Button w Display LDP 9030D 30 Flexible Button w Display LDP 9048DSS 48 Button DSS Console LDP 9208D 8 Flexible Button Display LDP 9224D 24 Flexible Button Display LDP 9224DF 24 Flexible Button Full duplex LDP 9240D 12 2 page Flexible Button Full duplex LDP 9248DSS 48 Flexible Button DSS Console LIP 7008D 8 Fl...

Page 81: ... 320 by 112 dot graphic LCD 8 flexible buttons and 3 soft keys LIP 9040 8 line 320 by 144 dot graphic LCD 12 flexible buttons and 3 soft keys LIP 9012DSS 12 flexible buttons with tri color LED LIP 9024DSS 24 flexible buttons with tri color LED LIP 9024LSS 12 flexible buttons with tri color LED two flexible button pages to represent 24 total flexible buttons LIP 9070 Premium Touch Screen IP Phone 7...

Page 82: ...ephones and Single Line Telephones and both must be wired with 22 or 24 AWG twisted pair Cat 3 or Cat 5 cable The wiring distance for IP phones is determined by the LAN and can be a maximum distance of 100 meters 328 feet from the LAN switch The IP phones are wired using Cat 5 cable for 10 100 Base T LANs and Cat5E cable for 1000 Base T LANs Figure 7 2 1 Terminal Wiring Distance ...

Page 83: ...tion point using UTP cable Note separate wiring is required for the LDP 7048 DSS Console 2 Using the line cord provided connect the DKTU or DSS Console to the wall outlet Modular Jack Pin Assignment Table 7 3 1 1 LDP 7200 series Modular Jack Wiring Connector Pin out Pin Number Signal Name RJ11 1 N A 2 RING 3 4 Reserved 5 TIP 6 N A Table 7 3 1 2 LDP 7000 and 9000 series Modular Jack Wiring Connecto...

Page 84: ...AC DC adaptor not both Use the Vertical approved AC DC power adaptor only The AC DC adaptor is ordered separately Modular Jack Pin Assignment Table 7 3 3 1 LIP Phone Modular Jack Wiring Connector Pin out Pin Number Signal Name Function RJ45 4 5 7 8 Reserved 1 TX Transmit Data 2 TX Transmit Data 3 RX Receive Data 6 RX Receive Data 1 Using the above wiring chart wire the RX and TX pins from the RJ45...

Page 85: ...ton 6 Press to exit and restart the LIP Phone Menu Display Description MODE R L LOCAL CHANGE Registration mode use to set Remote mode PHONE IP ADDRESS DOT Use the dial pad to enter the fixed IP address use DHCP for dynamic addressing PHONE NET MASK DOT Use the dial pad to enter the Subnet mask if using fixed IP addressing ROUTER IP ADDRESS DOT Use the dial pad to enter the default Gateway if using...

Page 86: ...48 DSS Console Wiring The LDP 7048 DSS Console is wired as a normal Digital Key Telephone to a separate digital port of the SUMMIT IP refer to Section 7 3 1 LIP 8000 Console Installation and Wiring The LIP 8000E Series DSS BLF Console is available in three 3 models 12 button w paper labels LIP 8012DSS 12 button w LCD LIP 8012LSS and 48 button w paper labels LIP 8048DSS Up to four 4 consoles can be...

Page 87: ...ng the Console serial cable connector 3 Insert the flat ribbon cable from the Console into the connector in the LIP phone 4 Insert and tighten two 2 screws through the DSS Console mounting flange into the LIP phone Caution do not over tighten the screws as this may damage the LIP phone housing 5 For additional Consoles repeat the procedure connecting one console to the previous console 6 For each ...

Page 88: ...h the phone The available button kits are shown in Figure 7 3 4 4 below and described as follows LIP 9012 DSS has 12 flexible buttons with tri color LED The DSS button kit uses a paper label for the button designations LIP 9024 DSS has 24 flexible buttons with tri color LED The DSS button kit uses a paper label for the button designations LIP 9024 LSS has 12 flexible buttons with tri color LED The...

Page 89: ...ected to power For convenience you may wish to remove the handset and foot stand this simplifies the Button kit installation 2 On the right side of the phone remove the Button kit cover 3 Align the Button kit and phone as shown in the drawing 4 Push the Button kit into the phone until the button kit is fully engaged 5 Insert the screws provided through the screw tabs in the Button kit and tighten ...

Page 90: ... the Wall Mount handset hook to prevent the handset from slipping when wall mounted 7 4 2 LIP 8000 8000E Wall Mount LIP 8000 8000E series phones incorporate wall mount into the base of the phone housing Using the instructions mount LIP 8000 8000E series phone on the wall An LIP phone with Consoles can be Wall Mounted after the Console is properly connected to the LIP phone refer to section 7 3 4 1...

Page 91: ...cket onto the phone applying steady pressure until it clicks into place 5 Install the Button kit wall mount bracket if required in the same manner as the bracket for the phone 6 Mark and drill two 7mm holes for plastic wall anchors not included 7 Insert the two anchors into the holes and insert and tighten the two screws not included leaving about 2 5 mm 1 8 inch exposed 8 Align the key holes in t...

Page 92: ...tem KSUs and the AC outlet 3 Turn the AC Power switches on the SUMMIT IP KSU and EKSU ON 4 Verify and if needed modify the Nation Code PGM100 with the DKT Section 8 2 1 or run the Install Wizard Section 8 3 5 Reset the SUMMIT IP KSU with either the recessed Reset button or by power cycling turn the AC Power switch OFF then ON 6 After the LEDs indicate normal operation refer to section 4 4 and chan...

Page 93: ...ystem as discussed in Section 8 1 with the new Nation Code Table 8 2 1 1 Nation Code Table COUNTRY CODE COUNTRY CODE COUNTRY CODE America 1 Argentina 54 Australia 61 Bahrain 973 Bangladesh 880 Belgium 32 Bolivia 591 Brazil 55 Brunei 673 Burma 95 Cameroon 237 Chile 56 China Taiwan 886 CIS 7 Colombia 57 Costa Rica 506 Cyprus 357 Czech 42 Denmark 45 Ecuador 593 Egypt 20 El Salvador 503 Ethiopia 251 F...

Page 94: ...that is accessed through the LAN port of the SUMMIT IP KSU Connect a PC to the LAN connected to the SUMMIT IP KSU LAN port or directly to the SUMMIT IP KSU LAN port Set the IP address of the PC to match the default system address 10 10 10 2 then follow the Steps below 1 System Upgrade 2 Nation Code 3 System Time Date 4 Station Number 5 Flexible Numbering Plan 6 CO Ring Assignment 7 License Upload ...

Page 95: ...rfaces analog CO Lines ISDN lines etc as well as the numbering plans for the specific country The gains in particular must be set to comply with the local regulatory requirements Normally the Nation Code will be set at the factory however assure the Nation code matches the system location If not turn SW 1 Pole 2 of KSU to ON change the Nation Code and save the page If the code is changed after sav...

Page 96: ...ardware Description and Installation Manual Issue 1 2 83 5 You can set System time and date in this page 6 You want to change the current station number to New station number In this page you can change the station number ...

Page 97: ...o access system resources outside lines page zones etc and features In the wizard codes for features that commonly may require modification are displayed 8 CO Ring Assignment establishes how the system will route incoming calls The wizard assignments cover all CO IP Lines in the system and the Ring assignments for Day Night and Timed Ring modes can be established ...

Page 98: ...license file can be shown in System Overview page 10 The Wizard includes a password entry page It is strongly recommended that a unique User ID and strong password be entered to minimize the risk of admin and maintenance access by unauthorized personnel In order to finish the final step you should register at least a maintenance ID If not so the Wizard can t go on to the next Also Keyset admin pas...

Page 99: ...c addressing can be configured When the system is behind a firewall the Firewall address must be entered allowing proper operation with remote users devise and SIP trunks A DNS Directory Name Server for Domain Name resolution should also be entered on this page Note that changing any IP address in the system requires a system reset the reset does not initialize data ...

Page 100: ...ich is a rated as 2A 250 Volts is located on the lower left of the PSU board To replace the fuse refer to the figure below and perform the following steps 1 Turn OFF the power to the KSU and the EKSU and extract the Power cord Plug 2 Remove the KSU cover refer to section 4 3 3 Remove the 3 screws holding the PSU cover and one screw inside in place 4 Lift and remove the PSU cover 5 Remove the fuse ...

Page 101: ...en the System and DKT Distance of DKT and System Check the distance between the MBU EMBU Option boards and the DKT Bad DKT Plug the DKT into another extension port that has been verified as working If the DKT still does not work properly replace the DKT SLT does not operate Bad MBU EMBU Option boards Exchange the board for one in good working condition Bad connection between the MBU EMBU Option bo...

Page 102: ...General Public License GPLv2 linux kernel GNU General Public License GPLv2 busybox GNU General Public License GPLv2 openldap OpenLDAP Public License BSD style openssl OpenSSL License and the original SSLeay license BSD style Open Source licenses Ericsson LG Enterprise offers to provide you with open source code on CD ROM for a charge covering the cost of performing such distribution such as the co...

Page 103: ... purchasing Vertical SUMMIT IP The contents of this document are subject to revision without notice due to continued progress in methodology design and manufacturing Ericsson LG Enterprise shall have no liability for any error or damage of any kind resulting from the use of this document ...

Reviews: