Vertical SUMMIT IP
Hardware Description and Installation Manual
Issue 1.2
54
The external batteries can maintain System operation for several hours depending on
several factors such as battery charge status, condition and capacity of the batteries, and
System configuration (active Station ports).
CAUTION
It is recommended to use an external backup battery fuse (10A@250V) between the
battery and the System.
Recommended battery capacity is 24V/20AH MF; the Vertical SUMMIT IP System
should be able to operate more than 3 hours with batteries that are in good condition.
Carefully check the battery polarity with cable colors (Red and Blue) when
connecting the battery to the System.
Do not short out the external batteries and cables.
Dispose of used batteries according to the manufacturer’s instructions.