GENERAL OPERATION
Operation - 41
Menu Options
To calibrate the slope gauge, change audible or visual
alert set-points, or to change the display screen, hold
your thumb over the slope gauge sensor for eight
seconds to enter the options menu. The option
screens
A
will display instructions for making changes
to the current feature. Swipe up across
the sensor to cycle through the menu
screens. Each swipe advances one
position to the next menu screen. The
dots (A) at the top of the screen allow
the user to see their screen position
(highlighted dot) in the menu.
Menu Screen 1
allows the user to
mute or enable the audible alarm. The
screen will display the current state of
the alarm. Hold over the sensor for three
seconds to change the setting.
Menu Screen 2
changes the audible
alarm set-point. Hold over the sensor until the set-
point angle begins to flash. Swipe up across the sen
-
sor to cycle through the set-point options.
Flashing
When the desired set-point is reached, hold over the
sensor to save the setting.
Menu Screen 3
changes the visual alarm set-point.
Hold over the sensor until the set-point angle begins
to flash. Swipe up across the sensor to cycle through
the set-point options.
Flashing
When the desired set-point is reached, hold over the
sensor to save the setting.
Menu Screen 4
calibrates the slope gauge. This zeros
out the gauge at the current position. Refer to the
slope gauge calibration section for calibration instruc-
tions.
Menu Screen 5
changes the screen display. There are
five screen display options from which the operator
can choose to display during operation. Hold over the
sensor until the factory default screen is displayed.
Swipe up to cycle through the display screen options.
Display Screen 1
is the factory
default screen and it displays the total
slope angle in degrees.
Display Screen 2
displays the
total slope angle in degrees, along with
the percentage of slope.
Display Screen 3
displays the
total slope angle in degrees, along
with a visual horizon and roll indicator.
Display Screen 4
displays the
total slope angle in degrees, along with
independent front-to-back angle and
side-to-side angle.
Display Screen 5
displays the
total slope angle in degrees, along with
independent front-to-back angle and
side-to-side angle with position indica-
tors.
When the desired screen is reached, hold over the
sensor to select and save. The slope gauge will re-
member the selected screen when the power unit is
shut off and will display the selected screen when the
power unit is restarted.
Menu Screen 6
resets the slope
gauge back to the factory default
settings. The audible alarm will be
turned on, and the audible and visual
set-points will be restored to 20 de-
grees. The slope gauge will need to be
recalibrated before operating the power
unit. Hold over the sensor until the
screen changes to show the default
audible and visual alarm settings. Hold
over the sensor again until the screen
changes to notify you that the reset was successful.
Menu Screen 7
exits the options
menu. Hold over the sensor to exit and
return to the display screen.