PDC movement
on X-Rail is very
slow while going
home in X -
Direction
Hand retrieves a
product, the PDC
appears to stop on X-
axis when it is near
the vend drop
position
Vend any product, make sure the X-movement
is smooth while the PDC is going to the home
position in X.
If the PDC appears to stop then move, change the
rollers in the X-carriage.
Hand stopping at
the middle of the
machine.
Hand moves to the
hopper above
position and stops.
1) Check the diagnostic message.
2) Check the hopper flap.
1) Perform action as defined in the error code.
2) Change flap motor if it is not working.
When the PDC is
away from the
'Home' position,
the rail moves
upward in Y-
direction and
stops.
The PDC moved in Y
direction but not in Z.
Service Mode:Activate PDC Software
Maintainance
Make sure the hand assembly is fitted evenly on the
L/R Z- tracks in the 'Hand Housing'.If the hand is off
the tracks - POWER DOWN.Separate the hand
assemly from the housing by rotating the Z-Motor
Encoder Wheel (black wheel visible once hand is
extended). Place the hand assemly evenly back onto
the left and right tracks. POWER ON. Wait during
Discovery.If performing this action does not correct the
problem, change the PDC hand.
The PDC Hand
crashes into the
flap.
1.The Y Motor
Encoder is potentially
malfunctioning.
2.The flap linkage is
broken
POWER DOWN
Disconnect the Flap motor.
1) POWER ON while the hand is away from
the home position.
2. Perform the flap test.
Check that the position of the hand is around the
middle of the vend flap when it is in the vend drop
mode.
1) If the vend drop position is below the normal
position,
change the Y Motor on the rail.
2) Ensure the link connecting the flap to the motor
is not broken.
Call Tech Service: 1-800-344-7216
The clamp closes
but does not open
fully.
While attempting to
operate, the clamp
fingers close but
cannot open to their
original position.
Test clamp motor in Test Motors Mode.
Perform Clamp Open test. If it does not open all the
way, check whether the compression spring is seated
correctly.
Perform Clamp Close test. In the clamp closed
position, check to see if the fingers are stuck.The
fingers should move easily when pushed out.
If the Clamp is working properly in 'Test Mode', change
the clamp sensor board.
In the problem persists, change the clamp motor.
Summary of Contents for VUE 30
Page 1: ...i 02 2006 TABLE OF CONTENTS...
Page 4: ...S 1 04 2005 SAFETY SECTION...
Page 7: ...S 4 04 2005 FIGURE 1...
Page 12: ...S 9 04 2005 FIGURE 3 8 0 AMP FUSE 3 15 AMP FUSE...
Page 20: ...S 17 04 2005 NOTES...
Page 21: ...G 1 04 2005 GENERAL INFORMATION SECTION...
Page 28: ...G 8 04 2005 NOTES...
Page 29: ...P 1 03 2006 VEC 15 PROGRAMMING SECTION...
Page 57: ...P 29 03 2006 NOTES...
Page 58: ...C 1 04 2006 CABINET SECTION...
Page 59: ...C 2 04 2006 1 2 3 4 5 6 7 8 3 9 10 12 13 14 13 13 16 15 11 18 19...
Page 63: ...C 6 04 2006 17 3 4 6 5 7 8 9 10 13 12 11 14 15 15 15 15 2 16 1...
Page 65: ...C 8 04 2006 19 20 15 3 16 9 15 13 11 10 12 14 2 8 15 6 5 4 7 15 1...
Page 68: ...C 11 04 2006 NOTES...
Page 69: ...ST 1 04 2006 SHELVES TRAYS PARTS SECTION...
Page 71: ...ST 3 04 2006 6 12 14 7 3 13 15 11 5 5 4 10 8 2 1 9 18 19 20 17 16 20 19 19...
Page 73: ...ST 5 04 2006 NOTES...
Page 74: ...D 1 05 2006 DOOR PARTS SECTION...
Page 75: ...D 2 05 2006 1 3 10 10 11 11 9 4 8 7 6 5 12 13 2...
Page 79: ...D 6 05 2006 1 2 3 9 8 13 12 13 11 17 16 15 14 5 4 7 6 10...
Page 82: ...D 9 05 2006 3 2 4 6 9 7 5 8 1127330 1125079 8 PTION PTION 1...
Page 84: ...D 11 05 2006 9 0QUJPO 1127330 1125080 1127891 1125941 8 PTION...
Page 88: ...D 15 05 2006 9 10 5 2 5 6 4 3 8 7 11 1...
Page 91: ...D 18 05 2006 1 7 10 8 9 12 12 3 2 5 6 11 12 13...
Page 95: ...D 22 05 2006 1 5 11 12 13 6 9 8 3 14 2 4 7 10 9 15 13 12...
Page 98: ...D 25 05 2006...
Page 99: ...M 1 04 2005 MAINTENANCE SECTION...
Page 107: ...M 9 04 2005 NOTES...
Page 129: ...PDC Hand Assembly...
Page 141: ......