Verify the evaporator fan is running.
Check harness to fan motor and check output voltage.
Test Mode - Relays: Evaporator Fan - attempt to turn
the evaporator fan on then off in this mode.
Miscellaneous Problems
Stuck Selection
SW on Keypad
Bad Selection Switch
- A Selection switch
inside the Keypad
was actuated more
than 15 seconds in
door closed, Sales
Mode, or door open,
Service Mode.
Check the selection switch number shown in
the detailed error code "nn" to see if:
1) The Keypad is defective
2) The harness is wired incorrectly or shorted
out.
The harness from the Ribbon Cable to the Selection
Switch Keypad could be upside down.
The # 2 slot on both the ribbon cable and harness
should be empty.
If this does not work, replace the Keypad.
Door Switch
Outer door has been
open for more than
one hour.
Check the vendor's door switch to see if it's
sticking or miswired.
Replace the door switch, if defective.
Ram Error
Ram check sum for
service mode settings
stored in non-volatile
memory has been
corrupted.
No test available.
If error shows up frequently, replace the control board.
AC Low
AC voltage to the
controller is less than
20Vrms for more than
30 seconds.
Check for low voltage at the wall outlet at
vendor start-up.
Contact a qualified electrician.
Scale
Scaling Factor error -
one of the credit
peripherals has
introduced a scaling
factor that is not
compatible with the
current configuration.
Check the connections of changer harness;
make sure changer is plugged in and working.
Make corrections to harness or replace the changer if
necessary.
Inlet Sensor
Machine's coin inlet
sensor is blocked for
more than 1 minute.
Check changer harnessing for cut, pinched or
crimped wires.
Make sure the coin return button is not pushed on the
vendor or on the coin mechanism.
Replace harnesses or changer.
Summary of Contents for VUE 30
Page 1: ...i 02 2006 TABLE OF CONTENTS...
Page 4: ...S 1 04 2005 SAFETY SECTION...
Page 7: ...S 4 04 2005 FIGURE 1...
Page 12: ...S 9 04 2005 FIGURE 3 8 0 AMP FUSE 3 15 AMP FUSE...
Page 20: ...S 17 04 2005 NOTES...
Page 21: ...G 1 04 2005 GENERAL INFORMATION SECTION...
Page 28: ...G 8 04 2005 NOTES...
Page 29: ...P 1 03 2006 VEC 15 PROGRAMMING SECTION...
Page 57: ...P 29 03 2006 NOTES...
Page 58: ...C 1 04 2006 CABINET SECTION...
Page 59: ...C 2 04 2006 1 2 3 4 5 6 7 8 3 9 10 12 13 14 13 13 16 15 11 18 19...
Page 63: ...C 6 04 2006 17 3 4 6 5 7 8 9 10 13 12 11 14 15 15 15 15 2 16 1...
Page 65: ...C 8 04 2006 19 20 15 3 16 9 15 13 11 10 12 14 2 8 15 6 5 4 7 15 1...
Page 68: ...C 11 04 2006 NOTES...
Page 69: ...ST 1 04 2006 SHELVES TRAYS PARTS SECTION...
Page 71: ...ST 3 04 2006 6 12 14 7 3 13 15 11 5 5 4 10 8 2 1 9 18 19 20 17 16 20 19 19...
Page 73: ...ST 5 04 2006 NOTES...
Page 74: ...D 1 05 2006 DOOR PARTS SECTION...
Page 75: ...D 2 05 2006 1 3 10 10 11 11 9 4 8 7 6 5 12 13 2...
Page 79: ...D 6 05 2006 1 2 3 9 8 13 12 13 11 17 16 15 14 5 4 7 6 10...
Page 82: ...D 9 05 2006 3 2 4 6 9 7 5 8 1127330 1125079 8 PTION PTION 1...
Page 84: ...D 11 05 2006 9 0QUJPO 1127330 1125080 1127891 1125941 8 PTION...
Page 88: ...D 15 05 2006 9 10 5 2 5 6 4 3 8 7 11 1...
Page 91: ...D 18 05 2006 1 7 10 8 9 12 12 3 2 5 6 11 12 13...
Page 95: ...D 22 05 2006 1 5 11 12 13 6 9 8 3 14 2 4 7 10 9 15 13 12...
Page 98: ...D 25 05 2006...
Page 99: ...M 1 04 2005 MAINTENANCE SECTION...
Page 107: ...M 9 04 2005 NOTES...
Page 129: ...PDC Hand Assembly...
Page 141: ......