If 'Y' Motor has not returned to the home
position, check to see if the hand is jammed on
a tray or other item in the cabinet.
Clear jam.
POWER DOWN, wait 5 seconds then POWER ON.
If hand (Y Motor) goes back home after 'Auto
Recovery', run 'Y' Motor test in Test Motors.
Complete a test vend cycle.
If hand does not go home in 'Y', replace 'Y' Motor.
If 'Y' Motor has returned to the home position,
hand jammed, but recovered, check product
positions to determine if any display 'sold out'
with product still in a column.
Complete a test vend cycle of sold out products.
If hand hits tray in Y, perform a Calibration Discovery
2.
Perform System Check, see X-Motor Jam.
POWER DOWN.
Replace fuse(s) if necessary.
POWER ON.
Complete a test vend cycle.
If unit is extended in 'Z' check 'Z' Housing
Ribbon Cable (within the hand) to be sure it is
plugged in.
Please refer to Diagram 1A
POWER DOWN.
Plug in 'Z' Housing Ribbon Cable.
POWER ON.
If hand goes back home after auto recovery, run 'Z'
Motor Test in Test Motors.
Complete a test vend cycle.
If a product is in the hand, perform a visual
check to see if the product is stopping the hand
from closing around it.
Remove product from hand.
POWER DOWN, wait 5 seconds. POWER ON. If hand
goes back home after auto recovery, run 'Z' Motor Test
in Test Motors. Complete a test vend cycle.
Z-motor Jam
Z' Motor portion of
vending mechanism
did not start or
complete.
If unit has returned to the home position, hand
jammed, but recovered, check product
positions to determine if any display 'sold out'
with product still in a column.
Complete a test vend cycle of sold out products.
If hand hits the tray front, run a Calibration Discovery
2.
If hand jams on center gate, reduce 'Z' Product
Position by 3 encodings in 'Calibration'. Please call
Tech Services at: 1-800-344-7216 for information
when attempting this function.
See X-Motor Jam information listed on prior
page.
POWER DOWN. Replace fuse(s) if necessary.
POWER ON
.
Complete a test vend cycle.
Clamp-motor Jam Clamp Motor did not
start or complete its
cycle.
Inspect clamp fingers to see if they are partially
open only.
Clamp motor has failed. Replace clamp motor.
Summary of Contents for VUE 30
Page 1: ...i 02 2006 TABLE OF CONTENTS...
Page 4: ...S 1 04 2005 SAFETY SECTION...
Page 7: ...S 4 04 2005 FIGURE 1...
Page 12: ...S 9 04 2005 FIGURE 3 8 0 AMP FUSE 3 15 AMP FUSE...
Page 20: ...S 17 04 2005 NOTES...
Page 21: ...G 1 04 2005 GENERAL INFORMATION SECTION...
Page 28: ...G 8 04 2005 NOTES...
Page 29: ...P 1 03 2006 VEC 15 PROGRAMMING SECTION...
Page 57: ...P 29 03 2006 NOTES...
Page 58: ...C 1 04 2006 CABINET SECTION...
Page 59: ...C 2 04 2006 1 2 3 4 5 6 7 8 3 9 10 12 13 14 13 13 16 15 11 18 19...
Page 63: ...C 6 04 2006 17 3 4 6 5 7 8 9 10 13 12 11 14 15 15 15 15 2 16 1...
Page 65: ...C 8 04 2006 19 20 15 3 16 9 15 13 11 10 12 14 2 8 15 6 5 4 7 15 1...
Page 68: ...C 11 04 2006 NOTES...
Page 69: ...ST 1 04 2006 SHELVES TRAYS PARTS SECTION...
Page 71: ...ST 3 04 2006 6 12 14 7 3 13 15 11 5 5 4 10 8 2 1 9 18 19 20 17 16 20 19 19...
Page 73: ...ST 5 04 2006 NOTES...
Page 74: ...D 1 05 2006 DOOR PARTS SECTION...
Page 75: ...D 2 05 2006 1 3 10 10 11 11 9 4 8 7 6 5 12 13 2...
Page 79: ...D 6 05 2006 1 2 3 9 8 13 12 13 11 17 16 15 14 5 4 7 6 10...
Page 82: ...D 9 05 2006 3 2 4 6 9 7 5 8 1127330 1125079 8 PTION PTION 1...
Page 84: ...D 11 05 2006 9 0QUJPO 1127330 1125080 1127891 1125941 8 PTION...
Page 88: ...D 15 05 2006 9 10 5 2 5 6 4 3 8 7 11 1...
Page 91: ...D 18 05 2006 1 7 10 8 9 12 12 3 2 5 6 11 12 13...
Page 95: ...D 22 05 2006 1 5 11 12 13 6 9 8 3 14 2 4 7 10 9 15 13 12...
Page 98: ...D 25 05 2006...
Page 99: ...M 1 04 2005 MAINTENANCE SECTION...
Page 107: ...M 9 04 2005 NOTES...
Page 129: ...PDC Hand Assembly...
Page 141: ......