background image

PART 2 - User manual

PART 2 - User manual

 

22

 

23

ATTACHING THE SHEETS

Place a slide sheet directly on top of the mattress, followed by the turning sheet 

which is then attached to the two bars. Slide sheets and turning sheets are available 

in standard bed sizes and with increased width which makes the VENDLET systems 

suitable for wider beds as well.

Turning sheet width

Slide sheet width

Fits mattress widths

350 cm (standard)

95 cm (standard)

80-90 cm (standard)

400 cm

115 cm

95-110 cm

450 cm

135 cm

115-130 cm

You can also purchase disposable turnings sheets and slide sheets. The disposable 

sheets are only avalible in one size.

Slide sheet

1.  Fold the slide sheet corner elastic straps 

around the mattress. 

2.  Check that the surface is smooth and even 

without creases and folds. Make sure that 

slippery side is facing upwards.

3.  Fasten the velcro tapes around 

the mattress frame. It is impor-

tant that the tapes are fastened around 

the frame under the mattress and not 

around the bed frame as this will prevent 

the back, thigh, and foot parts of the bed 

from being raised. The tapes are long 

enough for thick mattresses. 

The slide sheet is subject to extensive wear

 

and must be checked regularly. The friction of 

the turning sheet against the mattress will increase and the comfort of the client will 

be reduced during moving and other forms of handling if the bed is not fitted with a 

slide sheet or the slide sheet has been damaged.
When an alternating air mattress is fitted with a slide sheet, it is important that the 

velcro tapes are not fastened around the frame under the mattress too tightly as this 

could disrupt the function of the alternating air mattress. Consequently, the mattress 

should be fully inflated during fitting.

Turning sheet

Attaching the turning sheet before use

1.  Place the turning sheet in the middle of 

the bed, velcro tape facing downward.

2.  Press the turning sheet onto the velcro 

strip on one of the bars; begin at the head 

of the bed and work your way down to the 

foot of the bed.  

3.  The turning sheet must always 

be placed OVER the bars to prevent the 

fingers, hair ect. of the client from getting 

caught under the sheet. The pulling power 

will be reduced and the 

 

motors will switch off when the turning 

sheet is pulled in by the bar if the sheet is 

placed under the bars. 

4.  Press the 

 or 

 button on the hand 

control and allow approx. two-thirds of 

the sheet to be pulled in by the bar.

5.  Press the turning sheet onto the velcro 

strip on the opposite bar.  

6.  Use this bar to pull in the turning sheet by 

pressing the  

 or 

, button until the 

sheet covers the mattress evenly with the 

red line at the centre of the mattress.

What should I do if the turning sheet is rolled askew on the bars?

Occasionally, the turning sheet will roll askew on the bars. As such, this is insignificant 

and the VENDLET system will still be operable. 

This could result in turning sheet creases under the client, however, this is not 

 

desirable. Hence, we recommend that you aim to smooth the turning sheet if the 

sheet is askew on the bars by more than a hand’s width. 

In this situation, you will have to slacken the sheet that has been pulled askew and 

pull it in again while guiding / smoothing it with your hand.

Summary of Contents for V5S Speed Adjust

Page 1: ...VALUE IN CARING MANUAL VENDLET V5S VENDLET V5S VENDLET V5S VENDLET V5S Speed Adjust Speed Adjust...

Page 2: ...lateral prone or supine position moving from one side of the bed to the other repositioning the client up in the bed transferring the client from one bed to another This manual covers the following 4...

Page 3: ...3 Attaching the turning sheet before use 23 What should I do if the turning sheet is rolled askew on the bars 23 Changing the turning sheet on an occupied bed 24 DAILY MAINTENANCE 25 Daily inspections...

Page 4: ...transfer in the sheet minimises friction and the associated shear that can damage the tissue and cause pressure ulcers Furthermore the VENDLETs often seem to have a positive effect on clients sufferi...

Page 5: ...side rails Note This applies only to the VENDLET models that this manual covers How the VENDLET work The VENDLET are switched on by double clicking the on the hand control The VENDLET produce a beep u...

Page 6: ...is available to operate the VENDLET without a connec tion to the supply network We also provide an under bed light that may be activated via the VENDLET hand control see page 38 BED AND MATTRESS COMPA...

Page 7: ...d maintained in accordance with the guidelines in this manual IN THE EVENT OF AN INCIDENT In case of an adverse event or a near accident involving the VENDLET system the accident must be reported to t...

Page 8: ...e left arm of the client on his her stomach or chest the moment before he she starts turning 6 Immediately after this guide the right arm of the client to the side 7 Then shift the left leg in paralle...

Page 9: ...and so on until the sheet has been completely repositioned and the client is moved up in the bed again Gently guide the slack turning sheet towards the upper end of the bar The turning sheet is now a...

Page 10: ...ENDLET in combination with a slide board and a slide sheet may be used to transferring the client onto another bed 1 First use VENDLET s turning function to place the sliding board underneath the clie...

Page 11: ...lient is left unattended in the bed At the same time the velcro band on the slide sheet must not be fastened too tightly around the steel frame under the mattress If the alternating air mattress is ve...

Page 12: ...ortant that the velcro tapes are not fastened around the frame under the mattress too tightly as this could disrupt the function of the alternating air mattress Consequently the mattress should be ful...

Page 13: ...tion Yes No 4 Double click the on the hand control Does the green diode on the hand control illuminate Does everything work when you press the match ing hand control buttons Yes No 5 Has it been verif...

Page 14: ...to 230V outlet and is the power on Is the green diode on the control unit illuminated Are all plugs properly connected on the control unit Is the green diode on the hand control illuminated Double cl...

Page 15: ...Although the VENDLET systems are suitable for mounting on most beds with the above dimensions the VENDLET may not be suitable for mounting on some beds Before using a VENDLET system with a client it i...

Page 16: ...or VENDLET V5S and VENDLET V5S Speed Adjust is 200 kg The max user weight for VENDLET V5S and VENDLET V5S Speed Adjust is 400 kg Since the VENDLET systems are always mounted on beds it is important to...

Page 17: ...nt Always adjust the height of the VENDLET in accordance with the instructions on page 30 and the height of the mattress Use the positioning bolt on the backside of the mounting bracket to adjust the...

Page 18: ...ng away from the mounting bracket Push the spacers towards the mounting bracket contact face and attach them to the mounting bracket using the button head screws It is now possible to mount the mounti...

Page 19: ...plate for the control unit The control unit is mounted on the suspension plate There are two possible positions Tighten the suspension plate around the bed frame with the two fingerscrews The hand co...

Page 20: ...10 2 units Comfort System KR Opus FINAL INSPECTION CHECKLIST Always perform a final inspection after completing the installation The final inspection is carried out by following the checklist below Th...

Page 21: ...s the quick guide visible and located near the bed Is the VENDLET manual available Have the care givers been instructed on the use of the VENDLET and its functions Has the VENDLET system been signed u...

Page 22: ...ed Electrical parts Control unit no Check the control unit including plugs and mounting fittings for signs of damage Check whether the timer deactivates after 90 seconds of idle time Transformer no Ha...

Page 23: ...ection Is the plug properly connected to the control unit and the actuator Is the cable intact Switch the plugs of the two bars If the same bar still does not work then the bar motor is defective If t...

Page 24: ...se to disconnect the bar in both ends 4 Remove the Allen screw at the motor end of the bar and pull the motor out 5 Unscrew the small pivot screw on the motor fitting and remove it 6 Mount the motor f...

Page 25: ...ng cable ties for further details 9 Reconnect the power cable to the mains outlet 10 Reset the system by simultaneously pressing the two top buttons on the hand control You will hear a series of rhyth...

Page 26: ...NDITIONS AND DISPOSAL Environmental conditions Operation Temperature 5 40 C Air humidity 20 90 at 30 C no condensation Atmospheric pressure 700 1060 hPa Storage Temperature 10 50 C Air humidity 20 90...

Page 27: ...Vendlet ApS Egelund 33 6200 Aabenraa Tel 96 31 00 50 vendlet vendlet dk www vendlet dk All rights reserved Copyright 2016 Vendlet ApS Vers 1 1...