HAM841K GB
5
ALARM SENSOR
CONTACTS
ALARM SENSOR
CONTACTS
NOTE :
LINK 9 & 10 for
RECHARGEABLE BATTERY
DO NOT CONNECT
WHEN USING STANDARD
BATTERIES
Terminal 5 & 6 : N.C. Delayed-alarm Circuit
This circuit is controlled by the alarm on/off key switch. It should be used for any area requiring a delay between the
moment of detection and the activation of the siren. These contacts should be N.C., i.e. terminals 5 & 6 should be shorted
under normal circumstances. The delay is adjustable from 0.5 sec to 90 seconds by using the control marked "entry delay".
FIG. 4 : N.C. DELAYED-ALARM CIRCUIT
Terminal 6 & 7 : N.O. Delayed -alarm Circuit
This circuit has the same function as 5 & 6 but it is a N.O. circuit : the contact must be open under normal circumstances.
Ideal for pressure mats.
FIG.
5
:
N.O.
DELAYED-ALARM
CIRCUIT
Terminal 9 & 10 : Connections for Internal Battery Charger
These terminals should be linked to connect the internal battery charger to a rechargeable battery (we strongly advise you
to use a 12V rechargeable battery).
FIG. 6 : CONNECTIONS FOR RECHARGEABLE BATTERY