1AMP MAX. 

LIGHT 

Terminal 15 & 16 : Alarm memory relay contacts 
These contacts operate at the same time as the alarm relay contact. However, the contacts remain activated until the 
power is turned off or the alarm key switch is turned "off-on-off" (same as the Alarm Memory LED). It can be used to 
provide an external indication of the fact that the alarm has been triggered (alarm memory). Again, the max. current for the 
contact is 3 Amps. Power is connected in the same way as with terminals 13 and 14. 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

FIG. 10 : ALARM MEMORY RELAY CONNECTION - REMOTE ALARM MEMORY INDICATION 

 
 
 
 
Terminal 17 & 18 : Power input 
The polarity of these terminals is irrelevant if you have a 16V AC panel. Simply connect the two wires from the plug pack to 
these terminals. If you have a 12V DC panel, you should be careful to connect the power supply using the correct polarity : 
terminal 17 is positive (+), terminal 18 is negative (-)*. 
 

IMPORTANT : The standard Velleman version of this product is supplied with a 13.8VDC power supply !!! 
 

If you do not know which type of panel you have, you should check the area behind the terminals under the main circuit 
board. If you have a 16V AC panel, you will find a small auxiliary circuit board of approx. 50 x 25mm in this area. 
 
* Note : the DC input voltage should be 13.8V (or 14V) to ensure correct charging of the battery. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

FIG. 11 : POWER INPUT CONNECTION FOR AC OR DC POWER SUPPLY 

 

16VAC 

OR 

13.8VDC 

+VE 

-VE 

+ - 

Summary of Contents for HAM841K

Page 1: ...HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS USER MANUAL...

Page 2: ...ed by the internal buzzer that beeps 2 seconds on 1 4 second off during the alarm period This switch should be placed in the operate position for the siren and relays to operate normally 3 Duration Si...

Page 3: ...ory LED GREEN This LED will light when the alarm is triggered and will remain lit until the main power switch is turned off or until the key switch is turned off on off The alarm was triggered in your...

Page 4: ...siren motion sensors window switches window foil tapes etc can be connected here The contacts of these sensors should be shorted when in the normal reset condition and they should be arranged in a se...

Page 5: ...under normal circumstances The delay is adjustable from 0 5 sec to 90 seconds by using the control marked entry delay FIG 4 N C DELAYED ALARM CIRCUIT Terminal 6 7 N O Delayed alarm Circuit This circui...

Page 6: ...the 1K ohm resistor installed across the terminals should be left in place if no speaker is connected Remove this resistor if a speaker is connected FIG 7 CONNECTION FOR SPEAKER SIREN Terminal 13 14...

Page 7: ...ut The polarity of these terminals is irrelevant if you have a 16V AC panel Simply connect the two wires from the plug pack to these terminals If you have a 12V DC panel you should be careful to conne...

Page 8: ...ERMINAL FOR SWITCHABLE 12V POWER SOURCE Terminal 20 21 and 8 These terminals are used for remote key switches If no remote key switch is used terminals 20 and 21 should be shorted in order to disable...

Page 9: ...d should be linked in order to charge the battery NOTE When using standard batteries do not link terminals 9 10 to the battery use a 12V rechargeable battery SIREN WILL NOT SOUND Test Operate switch i...

Reviews: