HAM841K                                                                                                                                                                                               GB 

9

PROBLEM CHECKLIST 

 

PROBLEM POSSIBLE 

CAUSE 

 

 

BEEPER KEEPS SOUNDING 

-  Verify whether the speakers are connected 
-  When no speakers are used, the 1Kohm resistor should be 

connected across terminals 11 & 12 

-  Terminals 20 & 21 are not linked 
- Weak 

battery 

-  "Test/Operate"" switch is in the "Test"-position 
-  Beeper sounds during exit period 

INSTANT LED PERMANENTLY ON 

-  Terminals 1 & 2 are shorted (should be open) 
-  Terminals 2 & 3 are open (terminals 2 & 3 should be shorted if 

the alarm is not activated) 

DELAY LED PERMANENTLY ON 

-  Terminals 5 & 6 are open. They should be shorted if the alarm is 

not activated. 

-  Terminals 6 & 7 are shorted (should be open) 

LOW BATTERY INDICATION 

-  Terminals 9 & 10 are not linked (should be linked in order to 

charge the battery) 
NOTE : 

When using standard batteries, do not link terminals 
9 & 10 to the battery (use a 12V rechargeable 
battery) 

SIREN WILL NOT SOUND 

-  "Test/Operate" switch is in the "test"-position 
-  Wiring is cut 
-  1Kohm resistor has not been removed 

INSTANT-ALARM/DELAYED-ALARM CIRCUITS 
DO NOT WORK 

-  Key switch is not in the "on"-position 
-  Incorrect wiring : N.O. switch is wired in series or N.C. switch is 

wired in parallel 

 

CONNECTION TERMINALS 

 
 
  

FIRE/SMOKE 
SENSOR 

24 HOUR 
N.O.  
INSTANT 

N.C. 
SWITCHES 

N.C. 
INSTANT 

REMOTE 
ALARM 
STATUS 

N.C. 
SWITCHES 

N.C.  
DELAY 

N.O. 
SWITCHES 

N.O.  
DELAY 

ON           OFF

RECHARGEABLE BATTERY : CONNECTED 
NORMAL BATTERY - OPEN 

BATTERY 
CHARGER 

 HORN 

SPEAKER 
(MAX . TWO) 

INTELLIGENT 
SIREN DRIVER 
OUTPUT 

OUTPUT FOR ALARM 
RELAY CONTACT (3AMP 
MAX.) 

OUTPUT FOR ALARM 
MEMORY RELAY CONTACT 
(3AMP MAX.) 

12VDC (+) 

REMOTE KEY SWITCH 
WITH CUT WIRE PROTECTION 

+

POWER IN : SEE TEXT 

-

Summary of Contents for HAM841K

Page 1: ...HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS USER MANUAL...

Page 2: ...ed by the internal buzzer that beeps 2 seconds on 1 4 second off during the alarm period This switch should be placed in the operate position for the siren and relays to operate normally 3 Duration Si...

Page 3: ...ory LED GREEN This LED will light when the alarm is triggered and will remain lit until the main power switch is turned off or until the key switch is turned off on off The alarm was triggered in your...

Page 4: ...siren motion sensors window switches window foil tapes etc can be connected here The contacts of these sensors should be shorted when in the normal reset condition and they should be arranged in a se...

Page 5: ...under normal circumstances The delay is adjustable from 0 5 sec to 90 seconds by using the control marked entry delay FIG 4 N C DELAYED ALARM CIRCUIT Terminal 6 7 N O Delayed alarm Circuit This circui...

Page 6: ...the 1K ohm resistor installed across the terminals should be left in place if no speaker is connected Remove this resistor if a speaker is connected FIG 7 CONNECTION FOR SPEAKER SIREN Terminal 13 14...

Page 7: ...ut The polarity of these terminals is irrelevant if you have a 16V AC panel Simply connect the two wires from the plug pack to these terminals If you have a 12V DC panel you should be careful to conne...

Page 8: ...ERMINAL FOR SWITCHABLE 12V POWER SOURCE Terminal 20 21 and 8 These terminals are used for remote key switches If no remote key switch is used terminals 20 and 21 should be shorted in order to disable...

Page 9: ...d should be linked in order to charge the battery NOTE When using standard batteries do not link terminals 9 10 to the battery use a 12V rechargeable battery SIREN WILL NOT SOUND Test Operate switch i...

Reviews: