METHOD 2 

NOTE :  
TERMINALS 20 & 21 
MUST BE LINKED 

Terminal 19 : Switchable power output 
This terminal provides a 12V DC output of max. 0.5 Amps that is switched by the alarm on/off key switch. It can be used to supply 
ultrasonic or microwave motion detectors, etc. Avoid connection of infrared detectors to a switchable power supply. The PIR 
detectors should be connected to a permanent 12V power supply (terminal 21) in order to ensure stable and reliable operation. 
 
Connect the PIR detectors as follows : 
Positive connection (+) of the PIR detector to terminal 21 and the negative connection (-) to terminal 6. 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

FIG. 12 : TERMINAL FOR SWITCHABLE 12V POWER SOURCE 

 
Terminal 20, 21 and 8 
These terminals are used for remote key switches. If no remote key switch is used, terminals 20 and 21 should be shorted 
in order to disable the internal alarm that senses wire cutting. There are two ways to connect a remote key switch to the 
panel. Both methods (see diagram) will activate an internal alarm if the wiring is cut. 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

FIG. 13 : REMOTE KEYSWITCH WITH CUT WIRE PROTECTION 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

FIG. 14 : REMOTE KEYSWITCH WITH CUT WIRE PROTECTION 

NOTE : The key switch on the panel should be left in the "on"-position when an external key switch is being used. 
 
Both methods of remote key switch connection are secure : the alarm will be activated if the wiring is cut. 

METHOD 1 

+ 500mA MAX 

NOTE : 
CONNECT INFRARED DETECTORS 
TO TERMINAL 21 INSTEAD OF 19 

MICRO WAVE / 
ULTRASONIC 
DETECTORS 

Summary of Contents for HAM841K

Page 1: ...HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS USER MANUAL...

Page 2: ...ed by the internal buzzer that beeps 2 seconds on 1 4 second off during the alarm period This switch should be placed in the operate position for the siren and relays to operate normally 3 Duration Si...

Page 3: ...ory LED GREEN This LED will light when the alarm is triggered and will remain lit until the main power switch is turned off or until the key switch is turned off on off The alarm was triggered in your...

Page 4: ...siren motion sensors window switches window foil tapes etc can be connected here The contacts of these sensors should be shorted when in the normal reset condition and they should be arranged in a se...

Page 5: ...under normal circumstances The delay is adjustable from 0 5 sec to 90 seconds by using the control marked entry delay FIG 4 N C DELAYED ALARM CIRCUIT Terminal 6 7 N O Delayed alarm Circuit This circui...

Page 6: ...the 1K ohm resistor installed across the terminals should be left in place if no speaker is connected Remove this resistor if a speaker is connected FIG 7 CONNECTION FOR SPEAKER SIREN Terminal 13 14...

Page 7: ...ut The polarity of these terminals is irrelevant if you have a 16V AC panel Simply connect the two wires from the plug pack to these terminals If you have a 12V DC panel you should be careful to conne...

Page 8: ...ERMINAL FOR SWITCHABLE 12V POWER SOURCE Terminal 20 21 and 8 These terminals are used for remote key switches If no remote key switch is used terminals 20 and 21 should be shorted in order to disable...

Page 9: ...d should be linked in order to charge the battery NOTE When using standard batteries do not link terminals 9 10 to the battery use a 12V rechargeable battery SIREN WILL NOT SOUND Test Operate switch i...

Reviews: