USER MANUAL HAM841K
ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS
INTRODUCTION
The HAM841K (HA-841K) is a complete alarm control panel designed for commercial and residential security systems and
equipped with the latest electronic control technology. It has the highest level of quality and reliability. The exceptional
specifications incorporate many features that are generally only found in advanced professional systems. The HAM841K
(HA-841K) accepts active and passive sensors/detectors to form a versatile protection system.
NOTES FOR INSTALLING TECHNICIAN
The HAM841K panel is extremely reliable. Use the check list at the back of the manual in case of trouble. Recheck all the
wiring if the list does not help.
INTERNAL CONTROLS
1.
Main Power Switch :
Enables the user to disconnect or connect the power.
2.
Test/Operate Switch :
This switch allows the installer to test the panel without activating the siren or the relays. In the test position the siren
is replaced by the internal buzzer that beeps "2 seconds on 1/4 second off" during the alarm period. This switch
should be placed in the" operate" position for the siren and relays to operate normally.
3.
Duration Siren 24h / Panic Function / Fire :
Determines the length of time the siren will sound before resetting when it is triggered by the 24hr instant-alarm
circuit. This circuit is adjustable from 30 sec. to 3 min.
4.
Siren Duration / Burglary :
Determines the length of time the siren will sound before resetting when it is triggered by the N.C. (Normally Closed)
instant-alarm circuit or by the N.C. or N.O. (Normally Open) delayed-alarm circuits. The activation period is
adjustable from 30 sec. to 3 min.
5.
Entry Delay :
Determines the duration of the delay : from 0.5sec. to 90sec.
6.
Key Switch :
Switches alarm circuits on/off and does not affect the 24hr instant-alarm circuit.
CABINET LOCK
ALARM STATUS
INDICATOR
24-HOUR
PANIC BUTTON
POWER ON-OFF
KEY SWITCH
CONNECTION
TERMINALS
(SEE DESCRIPTION FOR
DETAILED INFORMATION )
MAIN POWER
ON-OFF SWITCH
BATTERY COMPARTMENT
WIRE FEED-
THROUGH HOLES
TEST/OPERATE
SELECTOR
ADJUSTS DURATION OF 24
HOUR PANIC/FIRE SIREN
ADJUSTS DURATION OF
BURGLARY SIREN
ADJUSTS DURATION OF
ENTRY DELAY